Cargando…

Mechanisms, predictors, and evolution of severe peri-device leaks with two different left atrial appendage occluders

AIMS: Incomplete left atrial appendage occlusion (LAAO) due to peri-device leak (PDL) is a limitation of the therapy. The Amulet IDE trial is the largest randomized head-to-head trial comparing the Amulet and Watchman 2.5 LAAO devices with fundamentally different designs. The predictors and mechanis...

Descripción completa

Detalles Bibliográficos
Autores principales: Lakkireddy, Dhanunjaya, Nielsen-Kudsk, Jens Erik, Windecker, Stephan, Thaler, David, Price, Matthew J, Gambhir, Alok, Gupta, Nigel, Koulogiannis, Konstantinos, Marcoff, Leo, Mediratta, Anuj, Anderson, Jordan A, Gage, Ryan, Ellis, Christopher R
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10427960/
https://www.ncbi.nlm.nih.gov/pubmed/37584233
http://dx.doi.org/10.1093/europace/euad237