Serotonin secretion by blood platelets: accuracy of high-performance liquid chromatography-electrochemical technique compared with the isotopic test and use in a clinical laboratory

BACKGROUND: Mild secretion defects are the most frequent and challenging blood platelet disorders to diagnose. Most δ-granule secretion tests lack validation, are not quantitative, or have unreliable response to weak platelet agonists. OBJECTIVES: To compare platelet serotonin secretion by HPLC-elec...

Descripción completa

Detalles Bibliográficos
Autores principales: Aranda, Eduardo, Iha, Seiki, Solari, Sandra, Rodríguez, David, Romero, Viviana, Villarroel, Luis, Pereira, Jaime, Panes, Olga, Mezzano, Diego
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10439442/
https://www.ncbi.nlm.nih.gov/pubmed/37601022
http://dx.doi.org/10.1016/j.rpth.2023.102156
_version_ 1785092945756553216
author Aranda, Eduardo
Iha, Seiki
Solari, Sandra
Rodríguez, David
Romero, Viviana
Villarroel, Luis
Pereira, Jaime
Panes, Olga
Mezzano, Diego
author_facet Aranda, Eduardo
Iha, Seiki
Solari, Sandra
Rodríguez, David
Romero, Viviana
Villarroel, Luis
Pereira, Jaime
Panes, Olga
Mezzano, Diego
author_sort Aranda, Eduardo
collection PubMed
description BACKGROUND: Mild secretion defects are the most frequent and challenging blood platelet disorders to diagnose. Most δ-granule secretion tests lack validation, are not quantitative, or have unreliable response to weak platelet agonists. OBJECTIVES: To compare platelet serotonin secretion by HPLC-electrochemical detection technique (HPLC-ECD) with the reference isotopic test ((3)H-5-HT), evaluating its performance in clinical laboratories. METHODS: The assay validation followed STARD-2015 recommendations. HPLC-ECD measured the nonsecreted serotonin remaining in platelet pellets after aggregation, comparing it with the reference (3)H-5-HT assay. We studied subjects with inherited and aspirin-induced blood platelet disorders and assessed the HPLC-ECD operation for routine clinical diagnosis. RESULTS: Calibration curves were linear (R(2) = 0.997), with SD for residuals of 3.91% and analytical sensitivity of 5ng/mL. Intra- and interassay imprecision bias ranged between −8.5% and 2.1% and −9% and 3.1%, respectively. Serotonin recovery and stability were >95%, and the variability range of measurements was −5.5% to 4.6%. Statistical differences detected between tests were biologically irrelevant, with bias of 1.48% (SD, 8.43) and CI agreement of −18% to 15%. Both assays distinctly detected platelet secretion induced by 10 μM epinephrine and 4 μmM adenosine diphosphate. However, HPLC-ECD is quantitative and more sensitive to low serotonin content in blood platelets. Reference cutoffs for each agonist were determined in 87 subjects. Initially, the HPLC-ECD requires relatively expensive equipment and trained operators but has remarkably cheap running costs and a turn-around time of 24-36 hours. We have used this diagnostic tool routinely for >8 years. CONCLUSION: HPLC-ECD assay for platelet serotonin secretion is highly accurate, has advantages over the reference (3)H-5-HT test, and is suitable as a clinical laboratory technique.
format Online
Article
Text
id pubmed-10439442
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-104394422023-08-20 Serotonin secretion by blood platelets: accuracy of high-performance liquid chromatography-electrochemical technique compared with the isotopic test and use in a clinical laboratory Aranda, Eduardo Iha, Seiki Solari, Sandra Rodríguez, David Romero, Viviana Villarroel, Luis Pereira, Jaime Panes, Olga Mezzano, Diego Res Pract Thromb Haemost Methodological Article BACKGROUND: Mild secretion defects are the most frequent and challenging blood platelet disorders to diagnose. Most δ-granule secretion tests lack validation, are not quantitative, or have unreliable response to weak platelet agonists. OBJECTIVES: To compare platelet serotonin secretion by HPLC-electrochemical detection technique (HPLC-ECD) with the reference isotopic test ((3)H-5-HT), evaluating its performance in clinical laboratories. METHODS: The assay validation followed STARD-2015 recommendations. HPLC-ECD measured the nonsecreted serotonin remaining in platelet pellets after aggregation, comparing it with the reference (3)H-5-HT assay. We studied subjects with inherited and aspirin-induced blood platelet disorders and assessed the HPLC-ECD operation for routine clinical diagnosis. RESULTS: Calibration curves were linear (R(2) = 0.997), with SD for residuals of 3.91% and analytical sensitivity of 5ng/mL. Intra- and interassay imprecision bias ranged between −8.5% and 2.1% and −9% and 3.1%, respectively. Serotonin recovery and stability were >95%, and the variability range of measurements was −5.5% to 4.6%. Statistical differences detected between tests were biologically irrelevant, with bias of 1.48% (SD, 8.43) and CI agreement of −18% to 15%. Both assays distinctly detected platelet secretion induced by 10 μM epinephrine and 4 μmM adenosine diphosphate. However, HPLC-ECD is quantitative and more sensitive to low serotonin content in blood platelets. Reference cutoffs for each agonist were determined in 87 subjects. Initially, the HPLC-ECD requires relatively expensive equipment and trained operators but has remarkably cheap running costs and a turn-around time of 24-36 hours. We have used this diagnostic tool routinely for >8 years. CONCLUSION: HPLC-ECD assay for platelet serotonin secretion is highly accurate, has advantages over the reference (3)H-5-HT test, and is suitable as a clinical laboratory technique. Elsevier 2023-07-24 /pmc/articles/PMC10439442/ /pubmed/37601022 http://dx.doi.org/10.1016/j.rpth.2023.102156 Text en © 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Methodological Article
Aranda, Eduardo
Iha, Seiki
Solari, Sandra
Rodríguez, David
Romero, Viviana
Villarroel, Luis
Pereira, Jaime
Panes, Olga
Mezzano, Diego
Serotonin secretion by blood platelets: accuracy of high-performance liquid chromatography-electrochemical technique compared with the isotopic test and use in a clinical laboratory
title Serotonin secretion by blood platelets: accuracy of high-performance liquid chromatography-electrochemical technique compared with the isotopic test and use in a clinical laboratory
title_full Serotonin secretion by blood platelets: accuracy of high-performance liquid chromatography-electrochemical technique compared with the isotopic test and use in a clinical laboratory
title_fullStr Serotonin secretion by blood platelets: accuracy of high-performance liquid chromatography-electrochemical technique compared with the isotopic test and use in a clinical laboratory
title_full_unstemmed Serotonin secretion by blood platelets: accuracy of high-performance liquid chromatography-electrochemical technique compared with the isotopic test and use in a clinical laboratory
title_short Serotonin secretion by blood platelets: accuracy of high-performance liquid chromatography-electrochemical technique compared with the isotopic test and use in a clinical laboratory
title_sort serotonin secretion by blood platelets: accuracy of high-performance liquid chromatography-electrochemical technique compared with the isotopic test and use in a clinical laboratory
topic Methodological Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10439442/
https://www.ncbi.nlm.nih.gov/pubmed/37601022
http://dx.doi.org/10.1016/j.rpth.2023.102156
work_keys_str_mv AT arandaeduardo serotoninsecretionbybloodplateletsaccuracyofhighperformanceliquidchromatographyelectrochemicaltechniquecomparedwiththeisotopictestanduseinaclinicallaboratory
AT ihaseiki serotoninsecretionbybloodplateletsaccuracyofhighperformanceliquidchromatographyelectrochemicaltechniquecomparedwiththeisotopictestanduseinaclinicallaboratory
AT solarisandra serotoninsecretionbybloodplateletsaccuracyofhighperformanceliquidchromatographyelectrochemicaltechniquecomparedwiththeisotopictestanduseinaclinicallaboratory
AT rodriguezdavid serotoninsecretionbybloodplateletsaccuracyofhighperformanceliquidchromatographyelectrochemicaltechniquecomparedwiththeisotopictestanduseinaclinicallaboratory
AT romeroviviana serotoninsecretionbybloodplateletsaccuracyofhighperformanceliquidchromatographyelectrochemicaltechniquecomparedwiththeisotopictestanduseinaclinicallaboratory
AT villarroelluis serotoninsecretionbybloodplateletsaccuracyofhighperformanceliquidchromatographyelectrochemicaltechniquecomparedwiththeisotopictestanduseinaclinicallaboratory
AT pereirajaime serotoninsecretionbybloodplateletsaccuracyofhighperformanceliquidchromatographyelectrochemicaltechniquecomparedwiththeisotopictestanduseinaclinicallaboratory
AT panesolga serotoninsecretionbybloodplateletsaccuracyofhighperformanceliquidchromatographyelectrochemicaltechniquecomparedwiththeisotopictestanduseinaclinicallaboratory
AT mezzanodiego serotoninsecretionbybloodplateletsaccuracyofhighperformanceliquidchromatographyelectrochemicaltechniquecomparedwiththeisotopictestanduseinaclinicallaboratory