The semi-analytic solution to the magnetic field of frequency-band-selecting eddy current testing for local corrosion flaw in large diameter pipeline

Local corrosion flaws (LCFs) widely exist in large diameter pipelines (LDPs) (e.g. steam, oil/gas pipeline) due to flow-accelerated corrosion, environmental corrosion, and material aging. Frequency-band-selecting eddy current testing (FBS-ECT), as an improved eddy current technique (ECT), has rich h...

Descripción completa

Detalles Bibliográficos
Autores principales: Fu, Kuan, Chen, Pengchao, Yu, Yating, Li, Rui, Fan, Yiming, Sun, Cheng, Liu, Bowen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10450344/
https://www.ncbi.nlm.nih.gov/pubmed/37143332
http://dx.doi.org/10.1177/00368504231172635