Cargando…

Assessment of Maturity of Plum Samples Using Fourier Transform Near-Infrared Technique Combined with Chemometric Methods

The FT-NIR technique was used for rapid and non-destructive determination of plum ripeness. The dry matter (DM), titratable acidity (TA), total soluble solids (TSS) and calculated maturity index (MI: TSS/TA) were used as reference values. The PLS correlations were validated via five-fold cross-valid...

Descripción completa

Detalles Bibliográficos
Autores principales: Fodor, Marietta, Jókai, Zsuzsa, Matkovits, Anna, Benes, Eszter
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10453540/
https://www.ncbi.nlm.nih.gov/pubmed/37628058
http://dx.doi.org/10.3390/foods12163059
_version_ 1785095962284261376
author Fodor, Marietta
Jókai, Zsuzsa
Matkovits, Anna
Benes, Eszter
author_facet Fodor, Marietta
Jókai, Zsuzsa
Matkovits, Anna
Benes, Eszter
author_sort Fodor, Marietta
collection PubMed
description The FT-NIR technique was used for rapid and non-destructive determination of plum ripeness. The dry matter (DM), titratable acidity (TA), total soluble solids (TSS) and calculated maturity index (MI: TSS/TA) were used as reference values. The PLS correlations were validated via five-fold cross-validation (RMSECV for different parameters: DM: 0.66%, w/w; TA = 0.07%, w/w; TSS = 0.72%, w/w; MI = 1.39) and test set validation (RMSEP for different parameters: DM: 0.65%, w/w TA = 0.07%, w/w; TSS = 0.61%, w/w; MI = 1.50). Different classification algorithms were performed for TA, TSS and MI. Linear, quadratic and Mahalanobis discriminant analysis (LDA, QDA, MDA) were found to be the best sample detection methods. The accuracy of the classification methods was 100% for all investigated parameters and cultivars.
format Online
Article
Text
id pubmed-10453540
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-104535402023-08-26 Assessment of Maturity of Plum Samples Using Fourier Transform Near-Infrared Technique Combined with Chemometric Methods Fodor, Marietta Jókai, Zsuzsa Matkovits, Anna Benes, Eszter Foods Article The FT-NIR technique was used for rapid and non-destructive determination of plum ripeness. The dry matter (DM), titratable acidity (TA), total soluble solids (TSS) and calculated maturity index (MI: TSS/TA) were used as reference values. The PLS correlations were validated via five-fold cross-validation (RMSECV for different parameters: DM: 0.66%, w/w; TA = 0.07%, w/w; TSS = 0.72%, w/w; MI = 1.39) and test set validation (RMSEP for different parameters: DM: 0.65%, w/w TA = 0.07%, w/w; TSS = 0.61%, w/w; MI = 1.50). Different classification algorithms were performed for TA, TSS and MI. Linear, quadratic and Mahalanobis discriminant analysis (LDA, QDA, MDA) were found to be the best sample detection methods. The accuracy of the classification methods was 100% for all investigated parameters and cultivars. MDPI 2023-08-15 /pmc/articles/PMC10453540/ /pubmed/37628058 http://dx.doi.org/10.3390/foods12163059 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Fodor, Marietta
Jókai, Zsuzsa
Matkovits, Anna
Benes, Eszter
Assessment of Maturity of Plum Samples Using Fourier Transform Near-Infrared Technique Combined with Chemometric Methods
title Assessment of Maturity of Plum Samples Using Fourier Transform Near-Infrared Technique Combined with Chemometric Methods
title_full Assessment of Maturity of Plum Samples Using Fourier Transform Near-Infrared Technique Combined with Chemometric Methods
title_fullStr Assessment of Maturity of Plum Samples Using Fourier Transform Near-Infrared Technique Combined with Chemometric Methods
title_full_unstemmed Assessment of Maturity of Plum Samples Using Fourier Transform Near-Infrared Technique Combined with Chemometric Methods
title_short Assessment of Maturity of Plum Samples Using Fourier Transform Near-Infrared Technique Combined with Chemometric Methods
title_sort assessment of maturity of plum samples using fourier transform near-infrared technique combined with chemometric methods
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10453540/
https://www.ncbi.nlm.nih.gov/pubmed/37628058
http://dx.doi.org/10.3390/foods12163059
work_keys_str_mv AT fodormarietta assessmentofmaturityofplumsamplesusingfouriertransformnearinfraredtechniquecombinedwithchemometricmethods
AT jokaizsuzsa assessmentofmaturityofplumsamplesusingfouriertransformnearinfraredtechniquecombinedwithchemometricmethods
AT matkovitsanna assessmentofmaturityofplumsamplesusingfouriertransformnearinfraredtechniquecombinedwithchemometricmethods
AT beneseszter assessmentofmaturityofplumsamplesusingfouriertransformnearinfraredtechniquecombinedwithchemometricmethods