Cargando…

Improving Pure Titanium’s Biological and Mechanical Characteristics through ECAP and Micro-Arc Oxidation Processes

Pure titanium is limited to be used in biomedical applications due to its lower mechanical strength compared to its alloy counterpart. To enhance its properties and improve medical implants feasibility, advancements in titanium processing technologies are necessary. One such technique is equal-chann...

Descripción completa

Detalles Bibliográficos
Autores principales: Alemayehu, Dawit Bogale, Todoh, Masahiro, Hsieh, Jang-Hsing, Li, Chuan, Huang, Song-Jeng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10456902/
https://www.ncbi.nlm.nih.gov/pubmed/37630077
http://dx.doi.org/10.3390/mi14081541