Cargando…

Removing a broken guidewire in the hip joint: treatment options and recommendations for preventing an avoidable surgical catastrophe. A case report: Removendo um fio-guia quebrado na articulação do quadril: opções de tratamento e recomendações para prevenir uma evitável catástrofe cirúrgica. Um relato de caso

CONTEXT: Hardware breakage during hip surgery can pose challenging and difficult problems for orthopedic surgeons. Apart from technical difficulties relating to retrieval of the broken hardware, complications such as adjacent joint arthritis and damage to neurovascular structures and major viscera c...

Descripción completa

Detalles Bibliográficos
Autores principales: Salunke, Abhijeet Ashok, Menon, Prem Haridas, Nambi, Gurunathampalayam Ilango, Tan, Junhao, Patel, Vivek, Chen, Yongsheng, Kumar, Jay
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Associação Paulista de Medicina - APM 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10496552/
https://www.ncbi.nlm.nih.gov/pubmed/26465811
http://dx.doi.org/10.1590/1516-3180.2014.9061512