Cargando…

Determination of the Diagnostic Performance of Laboratory Tests in the Absence of a Perfect Reference Standard: The Case of SARS-CoV-2 Tests

Background: Currently, assessing the diagnostic performance of new laboratory tests assumes a perfect reference standard, which is rarely the case. Wrong classifications of the true disease status will inevitably lead to biased estimates of sensitivity and specificity. Objectives: Using Bayesian’ la...

Descripción completa

Detalles Bibliográficos
Autores principales: Hartnack, Sonja, Nilius, Henning, Jegerlehner, Sabrina, Suter-Riniker, Franziska, Bittel, Pascal, Jent, Philipp, Nagler, Michael
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10530219/
https://www.ncbi.nlm.nih.gov/pubmed/37761259
http://dx.doi.org/10.3390/diagnostics13182892
_version_ 1785111486851448832
author Hartnack, Sonja
Nilius, Henning
Jegerlehner, Sabrina
Suter-Riniker, Franziska
Bittel, Pascal
Jent, Philipp
Nagler, Michael
author_facet Hartnack, Sonja
Nilius, Henning
Jegerlehner, Sabrina
Suter-Riniker, Franziska
Bittel, Pascal
Jent, Philipp
Nagler, Michael
author_sort Hartnack, Sonja
collection PubMed
description Background: Currently, assessing the diagnostic performance of new laboratory tests assumes a perfect reference standard, which is rarely the case. Wrong classifications of the true disease status will inevitably lead to biased estimates of sensitivity and specificity. Objectives: Using Bayesian’ latent class models (BLCMs), an approach that does not assume a perfect reference standard, we re-analyzed data of a large prospective observational study assessing the diagnostic accuracy of an antigen test for the diagnosis of SARS-CoV-2 infection in clinical practice. Methods: A cohort of consecutive patients presenting to a COVID-19 testing facility affiliated with a Swiss University Hospital were recruited (n = 1465). Two real-time PCR tests were conducted in parallel with the Roche/SD Biosensor rapid antigen test on nasopharyngeal swabs. A two-test (PCR and antigen test), three-population BLCM was fitted to the frequencies of paired test results. Results: Based on the BLCM, the sensitivities of the RT-PCR and the Roche/SD Biosensor rapid antigen test were 98.5% [95% CRI 94.8;100] and 82.7% [95% CRI 66.8;100]. The specificities were 97.7% [96.1;99.7] and 99.9% [95% CRI 99.6;100]. Conclusions: Applying the BLCM, the diagnostic accuracy of RT-PCR was high but not perfect. In contrast to previous results, the sensitivity of the antigen test was higher. Our results suggest that BLCMs are valuable tools for investigating the diagnostic performance of laboratory tests in the absence of perfect reference standard.
format Online
Article
Text
id pubmed-10530219
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-105302192023-09-28 Determination of the Diagnostic Performance of Laboratory Tests in the Absence of a Perfect Reference Standard: The Case of SARS-CoV-2 Tests Hartnack, Sonja Nilius, Henning Jegerlehner, Sabrina Suter-Riniker, Franziska Bittel, Pascal Jent, Philipp Nagler, Michael Diagnostics (Basel) Brief Report Background: Currently, assessing the diagnostic performance of new laboratory tests assumes a perfect reference standard, which is rarely the case. Wrong classifications of the true disease status will inevitably lead to biased estimates of sensitivity and specificity. Objectives: Using Bayesian’ latent class models (BLCMs), an approach that does not assume a perfect reference standard, we re-analyzed data of a large prospective observational study assessing the diagnostic accuracy of an antigen test for the diagnosis of SARS-CoV-2 infection in clinical practice. Methods: A cohort of consecutive patients presenting to a COVID-19 testing facility affiliated with a Swiss University Hospital were recruited (n = 1465). Two real-time PCR tests were conducted in parallel with the Roche/SD Biosensor rapid antigen test on nasopharyngeal swabs. A two-test (PCR and antigen test), three-population BLCM was fitted to the frequencies of paired test results. Results: Based on the BLCM, the sensitivities of the RT-PCR and the Roche/SD Biosensor rapid antigen test were 98.5% [95% CRI 94.8;100] and 82.7% [95% CRI 66.8;100]. The specificities were 97.7% [96.1;99.7] and 99.9% [95% CRI 99.6;100]. Conclusions: Applying the BLCM, the diagnostic accuracy of RT-PCR was high but not perfect. In contrast to previous results, the sensitivity of the antigen test was higher. Our results suggest that BLCMs are valuable tools for investigating the diagnostic performance of laboratory tests in the absence of perfect reference standard. MDPI 2023-09-09 /pmc/articles/PMC10530219/ /pubmed/37761259 http://dx.doi.org/10.3390/diagnostics13182892 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Brief Report
Hartnack, Sonja
Nilius, Henning
Jegerlehner, Sabrina
Suter-Riniker, Franziska
Bittel, Pascal
Jent, Philipp
Nagler, Michael
Determination of the Diagnostic Performance of Laboratory Tests in the Absence of a Perfect Reference Standard: The Case of SARS-CoV-2 Tests
title Determination of the Diagnostic Performance of Laboratory Tests in the Absence of a Perfect Reference Standard: The Case of SARS-CoV-2 Tests
title_full Determination of the Diagnostic Performance of Laboratory Tests in the Absence of a Perfect Reference Standard: The Case of SARS-CoV-2 Tests
title_fullStr Determination of the Diagnostic Performance of Laboratory Tests in the Absence of a Perfect Reference Standard: The Case of SARS-CoV-2 Tests
title_full_unstemmed Determination of the Diagnostic Performance of Laboratory Tests in the Absence of a Perfect Reference Standard: The Case of SARS-CoV-2 Tests
title_short Determination of the Diagnostic Performance of Laboratory Tests in the Absence of a Perfect Reference Standard: The Case of SARS-CoV-2 Tests
title_sort determination of the diagnostic performance of laboratory tests in the absence of a perfect reference standard: the case of sars-cov-2 tests
topic Brief Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10530219/
https://www.ncbi.nlm.nih.gov/pubmed/37761259
http://dx.doi.org/10.3390/diagnostics13182892
work_keys_str_mv AT hartnacksonja determinationofthediagnosticperformanceoflaboratorytestsintheabsenceofaperfectreferencestandardthecaseofsarscov2tests
AT niliushenning determinationofthediagnosticperformanceoflaboratorytestsintheabsenceofaperfectreferencestandardthecaseofsarscov2tests
AT jegerlehnersabrina determinationofthediagnosticperformanceoflaboratorytestsintheabsenceofaperfectreferencestandardthecaseofsarscov2tests
AT suterrinikerfranziska determinationofthediagnosticperformanceoflaboratorytestsintheabsenceofaperfectreferencestandardthecaseofsarscov2tests
AT bittelpascal determinationofthediagnosticperformanceoflaboratorytestsintheabsenceofaperfectreferencestandardthecaseofsarscov2tests
AT jentphilipp determinationofthediagnosticperformanceoflaboratorytestsintheabsenceofaperfectreferencestandardthecaseofsarscov2tests
AT naglermichael determinationofthediagnosticperformanceoflaboratorytestsintheabsenceofaperfectreferencestandardthecaseofsarscov2tests