Cargando…
Linking MS1 and MS2 signals in positive and negative modes of LC-HRMS in untargeted metabolomics using the ROIMCR approach
Data-independent acquisition (DIA) mode in liquid chromatography (LC) high-resolution mass spectrometry (HRMS) has emerged as a powerful strategy in untargeted metabolomics for detecting a broad range of metabolites. However, the use of this approach also represents a challenge in the analysis of th...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10558381/ https://www.ncbi.nlm.nih.gov/pubmed/37587312 http://dx.doi.org/10.1007/s00216-023-04893-3 |
_version_ | 1785117263088582656 |
---|---|
author | Yamamoto, Flávia Yoshie Pérez-López, Carlos Lopez-Antia, Ana Lacorte, Silvia de Souza Abessa, Denis Moledo Tauler, Romà |
author_facet | Yamamoto, Flávia Yoshie Pérez-López, Carlos Lopez-Antia, Ana Lacorte, Silvia de Souza Abessa, Denis Moledo Tauler, Romà |
author_sort | Yamamoto, Flávia Yoshie |
collection | PubMed |
description | Data-independent acquisition (DIA) mode in liquid chromatography (LC) high-resolution mass spectrometry (HRMS) has emerged as a powerful strategy in untargeted metabolomics for detecting a broad range of metabolites. However, the use of this approach also represents a challenge in the analysis of the large datasets generated. The regions of interest (ROI) multivariate curve resolution (MCR) approach can help in the identification and characterization of unknown metabolites in their mixtures by linking their MS1 and MS2 DIA spectral signals. In this study, it is proposed for the first time the analysis of MS1 and MS2 DIA signals in positive and negative electrospray ionization modes simultaneously to increase the coverage of possible metabolites present in biological systems. In this work, this approach has been tested for the detection and identification of the amino acids present in a standard mixture solution and in fish embryo samples. The ROIMCR analysis allowed for the identification of all amino acids present in the analyzed mixtures in both positive and negative modes. The methodology allowed for the direct linking and correspondence between the MS signals in their different acquisition modes. Overall, this approach confirmed the advantages and possibilities of performing the proposed ROIMCR simultaneous analysis of mass spectrometry signals in their differing acquisition modes in untargeted metabolomics studies. GRAPHICAL ABSTRACT: [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00216-023-04893-3. |
format | Online Article Text |
id | pubmed-10558381 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-105583812023-10-08 Linking MS1 and MS2 signals in positive and negative modes of LC-HRMS in untargeted metabolomics using the ROIMCR approach Yamamoto, Flávia Yoshie Pérez-López, Carlos Lopez-Antia, Ana Lacorte, Silvia de Souza Abessa, Denis Moledo Tauler, Romà Anal Bioanal Chem Research Paper Data-independent acquisition (DIA) mode in liquid chromatography (LC) high-resolution mass spectrometry (HRMS) has emerged as a powerful strategy in untargeted metabolomics for detecting a broad range of metabolites. However, the use of this approach also represents a challenge in the analysis of the large datasets generated. The regions of interest (ROI) multivariate curve resolution (MCR) approach can help in the identification and characterization of unknown metabolites in their mixtures by linking their MS1 and MS2 DIA spectral signals. In this study, it is proposed for the first time the analysis of MS1 and MS2 DIA signals in positive and negative electrospray ionization modes simultaneously to increase the coverage of possible metabolites present in biological systems. In this work, this approach has been tested for the detection and identification of the amino acids present in a standard mixture solution and in fish embryo samples. The ROIMCR analysis allowed for the identification of all amino acids present in the analyzed mixtures in both positive and negative modes. The methodology allowed for the direct linking and correspondence between the MS signals in their different acquisition modes. Overall, this approach confirmed the advantages and possibilities of performing the proposed ROIMCR simultaneous analysis of mass spectrometry signals in their differing acquisition modes in untargeted metabolomics studies. GRAPHICAL ABSTRACT: [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00216-023-04893-3. Springer Berlin Heidelberg 2023-08-17 2023 /pmc/articles/PMC10558381/ /pubmed/37587312 http://dx.doi.org/10.1007/s00216-023-04893-3 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Research Paper Yamamoto, Flávia Yoshie Pérez-López, Carlos Lopez-Antia, Ana Lacorte, Silvia de Souza Abessa, Denis Moledo Tauler, Romà Linking MS1 and MS2 signals in positive and negative modes of LC-HRMS in untargeted metabolomics using the ROIMCR approach |
title | Linking MS1 and MS2 signals in positive and negative modes of LC-HRMS in untargeted metabolomics using the ROIMCR approach |
title_full | Linking MS1 and MS2 signals in positive and negative modes of LC-HRMS in untargeted metabolomics using the ROIMCR approach |
title_fullStr | Linking MS1 and MS2 signals in positive and negative modes of LC-HRMS in untargeted metabolomics using the ROIMCR approach |
title_full_unstemmed | Linking MS1 and MS2 signals in positive and negative modes of LC-HRMS in untargeted metabolomics using the ROIMCR approach |
title_short | Linking MS1 and MS2 signals in positive and negative modes of LC-HRMS in untargeted metabolomics using the ROIMCR approach |
title_sort | linking ms1 and ms2 signals in positive and negative modes of lc-hrms in untargeted metabolomics using the roimcr approach |
topic | Research Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10558381/ https://www.ncbi.nlm.nih.gov/pubmed/37587312 http://dx.doi.org/10.1007/s00216-023-04893-3 |
work_keys_str_mv | AT yamamotoflaviayoshie linkingms1andms2signalsinpositiveandnegativemodesoflchrmsinuntargetedmetabolomicsusingtheroimcrapproach AT perezlopezcarlos linkingms1andms2signalsinpositiveandnegativemodesoflchrmsinuntargetedmetabolomicsusingtheroimcrapproach AT lopezantiaana linkingms1andms2signalsinpositiveandnegativemodesoflchrmsinuntargetedmetabolomicsusingtheroimcrapproach AT lacortesilvia linkingms1andms2signalsinpositiveandnegativemodesoflchrmsinuntargetedmetabolomicsusingtheroimcrapproach AT desouzaabessadenismoledo linkingms1andms2signalsinpositiveandnegativemodesoflchrmsinuntargetedmetabolomicsusingtheroimcrapproach AT taulerroma linkingms1andms2signalsinpositiveandnegativemodesoflchrmsinuntargetedmetabolomicsusingtheroimcrapproach |