Cargando…
Dosimetric evaluation of a spinal cord dose‐limiting 3D‐CRT technique for radiotherapy of spinal metastases
BACKGROUND: To evaluate the possible advantages of a simple spinal cord (SC) dose‐limiting three‐dimensional conformal radiotherapy (3D‐CRT) technique in comparison to conventional two‐dimensional (2D) techniques and other 3D‐CRT techniques for spinal bone irradiation. METHODS: For 41 spinal target...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2023
|
Materias: | |