Image-free handheld robotic-assisted technology improved the accuracy of implant positioning compared to conventional instrumentation in patients undergoing simultaneous bilateral total knee arthroplasty, without additional benefits in improvement of clinical outcomes
PURPOSE: The purpose of this study was to compare the clinical and radiological outcomes in patients who underwent simultaneous bilateral total knee arthroplasty (SB-TKA) using either robotic-assisted TKA (RA-TKA) or conventional TKA (C-TKA). METHODS: Included were the patients who underwent SB-TKA...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2023
|
Materias: | |