Image-free handheld robotic-assisted technology improved the accuracy of implant positioning compared to conventional instrumentation in patients undergoing simultaneous bilateral total knee arthroplasty, without additional benefits in improvement of clinical outcomes
PURPOSE: The purpose of this study was to compare the clinical and radiological outcomes in patients who underwent simultaneous bilateral total knee arthroplasty (SB-TKA) using either robotic-assisted TKA (RA-TKA) or conventional TKA (C-TKA). METHODS: Included were the patients who underwent SB-TKA...
Autores principales: | Albelooshi, Ali, Hamie, Muhieddine, Bollars, Peter, Althani, Saeed, Salameh, Rami, Almasri, Malak, Schotanus, Martijn G. M., Meshram, Prashant |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10598071/ https://www.ncbi.nlm.nih.gov/pubmed/37558748 http://dx.doi.org/10.1007/s00167-023-07523-8 |
Ejemplares similares
-
Consistency in patient-reported outcome measures after total knee arthroplasty using patient-specific instrumentation: a 5-year follow-up of 200 consecutive cases
por: Schoenmakers, Daphne A. L., et al.
Publicado: (2017) -
Intraoperative fluoroscopy improves surgical precision in conventional TKA
por: Hourlier, Hervé, et al.
Publicado: (2012) -
High intra- and inter-observer reliability of planning implant size in MRI-based patient-specific instrumentation for total knee arthroplasty
por: Schoenmakers, Daphne A. L., et al.
Publicado: (2020) -
Patient-specific guide for revision of medial unicondylar knee arthroplasty to total knee arthroplasty: Beneficial first results of a new operating technique performed on 10 patients
por: Kerens, Bart, et al.
Publicado: (2013) -
Preliminary experience with the patient-specific templating total knee arthroplasty: 40 cases compared with a matched control group
por: Boonen, Bert, et al.
Publicado: (2012)