Cargando…
The High-Efficiency Design Method for Capacitive MEMS Accelerometer
In this research, a high-efficiency design method of the capacitive MEMS accelerometer is proposed. As the MEMS accelerometer has high precision and a compact structure, much research has been carried out, which mainly focused on the structural design and materials selection. To overcome the inconve...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10609016/ https://www.ncbi.nlm.nih.gov/pubmed/37893328 http://dx.doi.org/10.3390/mi14101891 |
_version_ | 1785127914470113280 |
---|---|
author | Liu, Wen Zhao, Tianlong He, Zhiyuan Ye, Jingze Gong, Shaotong Wang, Xianglong Yang, Yintang |
author_facet | Liu, Wen Zhao, Tianlong He, Zhiyuan Ye, Jingze Gong, Shaotong Wang, Xianglong Yang, Yintang |
author_sort | Liu, Wen |
collection | PubMed |
description | In this research, a high-efficiency design method of the capacitive MEMS accelerometer is proposed. As the MEMS accelerometer has high precision and a compact structure, much research has been carried out, which mainly focused on the structural design and materials selection. To overcome the inconvenience and inaccuracy of the traditional design method, an orthogonal design and the particle swarm optimization (PSO) algorithm are introduced to improve the design efficiency. The whole process includes a finite element method (FEM) simulation, high-efficiency design, and verification. Through the theoretical analysis, the working mechanism of capacitive MEMS accelerometer is clear. Based on the comparison among the sweep calculation results of these parameters in the FEM software, four representative structural parameters are selected for further study, and they are l(e), n(f), l(f) and w(PM), respectively. l(e) and l(f) are the length of the sensing electrode and fixed electrode on the right. n(f) is the number of electrode pairs, and w(PM) is the width of the mass block. Then, in order to reduce computation, an orthogonal design is adopted and finally, 81 experimental groups are produced. Sensitivity S(V) and mass M(a) are defined as evaluation parameters, and structural parameters of experimental groups are imported into the FEM software to obtain the corresponding calculation results. These simulation data are imported into neural networks with the PSO algorithm. For a comprehensively accurate examination, three cases are used to verify our design method, and every case endows the performance parameters with different weights and expected values. The corresponding structural parameters of each case are given out after 24 iterations. Finally, the maximum calculation errors of S(V) and M(a) are 1.2941% and 0.1335%, respectively, proving the feasibility of the high-efficiency design method. |
format | Online Article Text |
id | pubmed-10609016 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-106090162023-10-28 The High-Efficiency Design Method for Capacitive MEMS Accelerometer Liu, Wen Zhao, Tianlong He, Zhiyuan Ye, Jingze Gong, Shaotong Wang, Xianglong Yang, Yintang Micromachines (Basel) Article In this research, a high-efficiency design method of the capacitive MEMS accelerometer is proposed. As the MEMS accelerometer has high precision and a compact structure, much research has been carried out, which mainly focused on the structural design and materials selection. To overcome the inconvenience and inaccuracy of the traditional design method, an orthogonal design and the particle swarm optimization (PSO) algorithm are introduced to improve the design efficiency. The whole process includes a finite element method (FEM) simulation, high-efficiency design, and verification. Through the theoretical analysis, the working mechanism of capacitive MEMS accelerometer is clear. Based on the comparison among the sweep calculation results of these parameters in the FEM software, four representative structural parameters are selected for further study, and they are l(e), n(f), l(f) and w(PM), respectively. l(e) and l(f) are the length of the sensing electrode and fixed electrode on the right. n(f) is the number of electrode pairs, and w(PM) is the width of the mass block. Then, in order to reduce computation, an orthogonal design is adopted and finally, 81 experimental groups are produced. Sensitivity S(V) and mass M(a) are defined as evaluation parameters, and structural parameters of experimental groups are imported into the FEM software to obtain the corresponding calculation results. These simulation data are imported into neural networks with the PSO algorithm. For a comprehensively accurate examination, three cases are used to verify our design method, and every case endows the performance parameters with different weights and expected values. The corresponding structural parameters of each case are given out after 24 iterations. Finally, the maximum calculation errors of S(V) and M(a) are 1.2941% and 0.1335%, respectively, proving the feasibility of the high-efficiency design method. MDPI 2023-09-30 /pmc/articles/PMC10609016/ /pubmed/37893328 http://dx.doi.org/10.3390/mi14101891 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Liu, Wen Zhao, Tianlong He, Zhiyuan Ye, Jingze Gong, Shaotong Wang, Xianglong Yang, Yintang The High-Efficiency Design Method for Capacitive MEMS Accelerometer |
title | The High-Efficiency Design Method for Capacitive MEMS Accelerometer |
title_full | The High-Efficiency Design Method for Capacitive MEMS Accelerometer |
title_fullStr | The High-Efficiency Design Method for Capacitive MEMS Accelerometer |
title_full_unstemmed | The High-Efficiency Design Method for Capacitive MEMS Accelerometer |
title_short | The High-Efficiency Design Method for Capacitive MEMS Accelerometer |
title_sort | high-efficiency design method for capacitive mems accelerometer |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10609016/ https://www.ncbi.nlm.nih.gov/pubmed/37893328 http://dx.doi.org/10.3390/mi14101891 |
work_keys_str_mv | AT liuwen thehighefficiencydesignmethodforcapacitivememsaccelerometer AT zhaotianlong thehighefficiencydesignmethodforcapacitivememsaccelerometer AT hezhiyuan thehighefficiencydesignmethodforcapacitivememsaccelerometer AT yejingze thehighefficiencydesignmethodforcapacitivememsaccelerometer AT gongshaotong thehighefficiencydesignmethodforcapacitivememsaccelerometer AT wangxianglong thehighefficiencydesignmethodforcapacitivememsaccelerometer AT yangyintang thehighefficiencydesignmethodforcapacitivememsaccelerometer AT liuwen highefficiencydesignmethodforcapacitivememsaccelerometer AT zhaotianlong highefficiencydesignmethodforcapacitivememsaccelerometer AT hezhiyuan highefficiencydesignmethodforcapacitivememsaccelerometer AT yejingze highefficiencydesignmethodforcapacitivememsaccelerometer AT gongshaotong highefficiencydesignmethodforcapacitivememsaccelerometer AT wangxianglong highefficiencydesignmethodforcapacitivememsaccelerometer AT yangyintang highefficiencydesignmethodforcapacitivememsaccelerometer |