Cargando…

The High-Efficiency Design Method for Capacitive MEMS Accelerometer

In this research, a high-efficiency design method of the capacitive MEMS accelerometer is proposed. As the MEMS accelerometer has high precision and a compact structure, much research has been carried out, which mainly focused on the structural design and materials selection. To overcome the inconve...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Wen, Zhao, Tianlong, He, Zhiyuan, Ye, Jingze, Gong, Shaotong, Wang, Xianglong, Yang, Yintang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10609016/
https://www.ncbi.nlm.nih.gov/pubmed/37893328
http://dx.doi.org/10.3390/mi14101891
_version_ 1785127914470113280
author Liu, Wen
Zhao, Tianlong
He, Zhiyuan
Ye, Jingze
Gong, Shaotong
Wang, Xianglong
Yang, Yintang
author_facet Liu, Wen
Zhao, Tianlong
He, Zhiyuan
Ye, Jingze
Gong, Shaotong
Wang, Xianglong
Yang, Yintang
author_sort Liu, Wen
collection PubMed
description In this research, a high-efficiency design method of the capacitive MEMS accelerometer is proposed. As the MEMS accelerometer has high precision and a compact structure, much research has been carried out, which mainly focused on the structural design and materials selection. To overcome the inconvenience and inaccuracy of the traditional design method, an orthogonal design and the particle swarm optimization (PSO) algorithm are introduced to improve the design efficiency. The whole process includes a finite element method (FEM) simulation, high-efficiency design, and verification. Through the theoretical analysis, the working mechanism of capacitive MEMS accelerometer is clear. Based on the comparison among the sweep calculation results of these parameters in the FEM software, four representative structural parameters are selected for further study, and they are l(e), n(f), l(f) and w(PM), respectively. l(e) and l(f) are the length of the sensing electrode and fixed electrode on the right. n(f) is the number of electrode pairs, and w(PM) is the width of the mass block. Then, in order to reduce computation, an orthogonal design is adopted and finally, 81 experimental groups are produced. Sensitivity S(V) and mass M(a) are defined as evaluation parameters, and structural parameters of experimental groups are imported into the FEM software to obtain the corresponding calculation results. These simulation data are imported into neural networks with the PSO algorithm. For a comprehensively accurate examination, three cases are used to verify our design method, and every case endows the performance parameters with different weights and expected values. The corresponding structural parameters of each case are given out after 24 iterations. Finally, the maximum calculation errors of S(V) and M(a) are 1.2941% and 0.1335%, respectively, proving the feasibility of the high-efficiency design method.
format Online
Article
Text
id pubmed-10609016
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-106090162023-10-28 The High-Efficiency Design Method for Capacitive MEMS Accelerometer Liu, Wen Zhao, Tianlong He, Zhiyuan Ye, Jingze Gong, Shaotong Wang, Xianglong Yang, Yintang Micromachines (Basel) Article In this research, a high-efficiency design method of the capacitive MEMS accelerometer is proposed. As the MEMS accelerometer has high precision and a compact structure, much research has been carried out, which mainly focused on the structural design and materials selection. To overcome the inconvenience and inaccuracy of the traditional design method, an orthogonal design and the particle swarm optimization (PSO) algorithm are introduced to improve the design efficiency. The whole process includes a finite element method (FEM) simulation, high-efficiency design, and verification. Through the theoretical analysis, the working mechanism of capacitive MEMS accelerometer is clear. Based on the comparison among the sweep calculation results of these parameters in the FEM software, four representative structural parameters are selected for further study, and they are l(e), n(f), l(f) and w(PM), respectively. l(e) and l(f) are the length of the sensing electrode and fixed electrode on the right. n(f) is the number of electrode pairs, and w(PM) is the width of the mass block. Then, in order to reduce computation, an orthogonal design is adopted and finally, 81 experimental groups are produced. Sensitivity S(V) and mass M(a) are defined as evaluation parameters, and structural parameters of experimental groups are imported into the FEM software to obtain the corresponding calculation results. These simulation data are imported into neural networks with the PSO algorithm. For a comprehensively accurate examination, three cases are used to verify our design method, and every case endows the performance parameters with different weights and expected values. The corresponding structural parameters of each case are given out after 24 iterations. Finally, the maximum calculation errors of S(V) and M(a) are 1.2941% and 0.1335%, respectively, proving the feasibility of the high-efficiency design method. MDPI 2023-09-30 /pmc/articles/PMC10609016/ /pubmed/37893328 http://dx.doi.org/10.3390/mi14101891 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Liu, Wen
Zhao, Tianlong
He, Zhiyuan
Ye, Jingze
Gong, Shaotong
Wang, Xianglong
Yang, Yintang
The High-Efficiency Design Method for Capacitive MEMS Accelerometer
title The High-Efficiency Design Method for Capacitive MEMS Accelerometer
title_full The High-Efficiency Design Method for Capacitive MEMS Accelerometer
title_fullStr The High-Efficiency Design Method for Capacitive MEMS Accelerometer
title_full_unstemmed The High-Efficiency Design Method for Capacitive MEMS Accelerometer
title_short The High-Efficiency Design Method for Capacitive MEMS Accelerometer
title_sort high-efficiency design method for capacitive mems accelerometer
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10609016/
https://www.ncbi.nlm.nih.gov/pubmed/37893328
http://dx.doi.org/10.3390/mi14101891
work_keys_str_mv AT liuwen thehighefficiencydesignmethodforcapacitivememsaccelerometer
AT zhaotianlong thehighefficiencydesignmethodforcapacitivememsaccelerometer
AT hezhiyuan thehighefficiencydesignmethodforcapacitivememsaccelerometer
AT yejingze thehighefficiencydesignmethodforcapacitivememsaccelerometer
AT gongshaotong thehighefficiencydesignmethodforcapacitivememsaccelerometer
AT wangxianglong thehighefficiencydesignmethodforcapacitivememsaccelerometer
AT yangyintang thehighefficiencydesignmethodforcapacitivememsaccelerometer
AT liuwen highefficiencydesignmethodforcapacitivememsaccelerometer
AT zhaotianlong highefficiencydesignmethodforcapacitivememsaccelerometer
AT hezhiyuan highefficiencydesignmethodforcapacitivememsaccelerometer
AT yejingze highefficiencydesignmethodforcapacitivememsaccelerometer
AT gongshaotong highefficiencydesignmethodforcapacitivememsaccelerometer
AT wangxianglong highefficiencydesignmethodforcapacitivememsaccelerometer
AT yangyintang highefficiencydesignmethodforcapacitivememsaccelerometer