Inverse planning optimization with lead block effectively suppresses dose to the mandible in high-dose-rate brachytherapy for tongue cancer

PURPOSE: In this study, we developed in-house software to evaluate the effect of the lead block (LB)-inserted spacer on the mandibular dose in interstitial brachytherapy (ISBT) for tongue cancer. In addition, an inverse planning algorithm for LB attenuation was developed, and its performance in mand...

Descripción completa

Detalles Bibliográficos
Autores principales: Akino, Yuichi, Shiomi, Hiroya, Tsujimoto, Tomomi, Hamatani, Noriaki, Hirata, Takero, Oda, Michio, Takeshita, Ami, Shimamoto, Hiroaki, Ogawa, Kazuhiko, Murakami, Shumei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Nature Singapore 2023