Improved first-pass effect in acute stroke thrombectomy using Solitaire-X compared to Solitaire-FR
BACKGROUND: In acute ischemic stroke (AIS), successful endovascular thrombectomy (EVT) of large vessel occlusion (LVO) necessitates the most suited device. Solitaire-X has longer and larger diameter pusher wires than Solitaire-FR. As the role of a larger pusher-wire diameter is uncertain, we aim to...