Unrestricted kinematic alignment corrects fixed flexion contracture in robotically aligned total knees without raising the joint line in extension

PURPOSE: Mechanically Aligned Total Knee Arthroplasty (MA TKA) typically addresses fixed flexion contractures (FFC) by raising the joint line during extension. However, in unrestricted Kinematically Aligned TKA (KA TKA) utilizing a caliper-based resection technique, the joint line is not raised. Thi...