Membrane Resistance of Human Red Cells
A method has been devised to measure the specific membrane resistance of single human red cells. The cells were sucked into a 3 to 5 micron diameter pore in the end of a glass tube. By passing a small current through the cells, the total cell resistance was measured. The dimensions of the cell were...