Membrane Currents in Mammalian Ventricular Heart Muscle Fibers Using a Voltage-Clamp Technique

Bundles of sheep ventricular fibers were voltage-clamped utilizing a modified sucrose gap technique and intracellular voltage control. An action potential was fired off in the usual way, and the clamp circuit was switched on at preselected times during activity. Clamping the membrane back to its res...

Descripción completa

Detalles Bibliográficos
Autores principales: Giebisch, Gerhard, Weidmann, Silvio
Formato: Texto
Lenguaje:English
Publicado: The Rockefeller University Press 1971