Tracer Determinations of Human Red Cell Membrane Permeability to Small Nonelectrolytes
A flow system has been used to determine the permeability of human red cell membranes to four small nonelectrolytes labeled with (14)C. The permeability coefficients, ω, in units of mol dyne(-1) sec(-1) x 10(15), are: ethylene glycol, 6; urea, 13; formamide, 22; and methanol, 131. The values for ure...