Cargando…

Tumor volume in subcutaneous mouse xenografts measured by microCT is more accurate and reproducible than determined by (18)F-FDG-microPET or external caliper

BACKGROUND: In animal studies tumor size is used to assess responses to anticancer therapy. Current standard for volumetric measurement of xenografted tumors is by external caliper, a method often affected by error. The aim of the present study was to evaluate if microCT gives more accurate and repr...

Descripción completa

Detalles Bibliográficos
Autores principales: Jensen, Mette Munk, Jørgensen, Jesper Tranekjær, Binderup, Tina, Kjær, Andreas
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2008