Microfludic Device for Creating Ionic Strength Gradients over DNA Microarrays for Efficient DNA Melting Studies and Assay Development
The development of DNA microarray assays is hampered by two important aspects: processing of the microarrays is done under a single stringency condition, and characteristics such as melting temperature are difficult to predict for immobilized probes. A technical solution to these limitations is to u...
Autores principales: | , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2653225/ https://www.ncbi.nlm.nih.gov/pubmed/19277213 http://dx.doi.org/10.1371/journal.pone.0004808 |
_version_ | 1782165268920795136 |
---|---|
author | Petersen, Jesper Poulsen, Lena Birgens, Henrik Dufva, Martin |
author_facet | Petersen, Jesper Poulsen, Lena Birgens, Henrik Dufva, Martin |
author_sort | Petersen, Jesper |
collection | PubMed |
description | The development of DNA microarray assays is hampered by two important aspects: processing of the microarrays is done under a single stringency condition, and characteristics such as melting temperature are difficult to predict for immobilized probes. A technical solution to these limitations is to use a thermal gradient and information from melting curves, for instance to score genotypes. However, application of temperature gradients normally requires complicated equipment, and the size of the arrays that can be investigated is restricted due to heat dissipation. Here we present a simple microfluidic device that creates a gradient comprising zones of defined ionic strength over a glass slide, in which each zone corresponds to a subarray. Using this device, we demonstrated that ionic strength gradients function in a similar fashion as corresponding thermal gradients in assay development. More specifically, we noted that (i) the two stringency modulators generated melting curves that could be compared, (ii) both led to increased assay robustness, and (iii) both were associated with difficulties in genotyping the same mutation. These findings demonstrate that ionic strength stringency buffers can be used instead of thermal gradients. Given the flexibility of design of ionic gradients, these can be created over all types of arrays, and encompass an attractive alternative to temperature gradients, avoiding curtailment of the size or spacing of subarrays on slides associated with temperature gradients. |
format | Text |
id | pubmed-2653225 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2009 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-26532252009-03-11 Microfludic Device for Creating Ionic Strength Gradients over DNA Microarrays for Efficient DNA Melting Studies and Assay Development Petersen, Jesper Poulsen, Lena Birgens, Henrik Dufva, Martin PLoS One Research Article The development of DNA microarray assays is hampered by two important aspects: processing of the microarrays is done under a single stringency condition, and characteristics such as melting temperature are difficult to predict for immobilized probes. A technical solution to these limitations is to use a thermal gradient and information from melting curves, for instance to score genotypes. However, application of temperature gradients normally requires complicated equipment, and the size of the arrays that can be investigated is restricted due to heat dissipation. Here we present a simple microfluidic device that creates a gradient comprising zones of defined ionic strength over a glass slide, in which each zone corresponds to a subarray. Using this device, we demonstrated that ionic strength gradients function in a similar fashion as corresponding thermal gradients in assay development. More specifically, we noted that (i) the two stringency modulators generated melting curves that could be compared, (ii) both led to increased assay robustness, and (iii) both were associated with difficulties in genotyping the same mutation. These findings demonstrate that ionic strength stringency buffers can be used instead of thermal gradients. Given the flexibility of design of ionic gradients, these can be created over all types of arrays, and encompass an attractive alternative to temperature gradients, avoiding curtailment of the size or spacing of subarrays on slides associated with temperature gradients. Public Library of Science 2009-03-11 /pmc/articles/PMC2653225/ /pubmed/19277213 http://dx.doi.org/10.1371/journal.pone.0004808 Text en Petersen et al. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Petersen, Jesper Poulsen, Lena Birgens, Henrik Dufva, Martin Microfludic Device for Creating Ionic Strength Gradients over DNA Microarrays for Efficient DNA Melting Studies and Assay Development |
title | Microfludic Device for Creating Ionic Strength Gradients over DNA Microarrays for Efficient DNA Melting Studies and Assay Development |
title_full | Microfludic Device for Creating Ionic Strength Gradients over DNA Microarrays for Efficient DNA Melting Studies and Assay Development |
title_fullStr | Microfludic Device for Creating Ionic Strength Gradients over DNA Microarrays for Efficient DNA Melting Studies and Assay Development |
title_full_unstemmed | Microfludic Device for Creating Ionic Strength Gradients over DNA Microarrays for Efficient DNA Melting Studies and Assay Development |
title_short | Microfludic Device for Creating Ionic Strength Gradients over DNA Microarrays for Efficient DNA Melting Studies and Assay Development |
title_sort | microfludic device for creating ionic strength gradients over dna microarrays for efficient dna melting studies and assay development |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2653225/ https://www.ncbi.nlm.nih.gov/pubmed/19277213 http://dx.doi.org/10.1371/journal.pone.0004808 |
work_keys_str_mv | AT petersenjesper microfludicdeviceforcreatingionicstrengthgradientsoverdnamicroarraysforefficientdnameltingstudiesandassaydevelopment AT poulsenlena microfludicdeviceforcreatingionicstrengthgradientsoverdnamicroarraysforefficientdnameltingstudiesandassaydevelopment AT birgenshenrik microfludicdeviceforcreatingionicstrengthgradientsoverdnamicroarraysforefficientdnameltingstudiesandassaydevelopment AT dufvamartin microfludicdeviceforcreatingionicstrengthgradientsoverdnamicroarraysforefficientdnameltingstudiesandassaydevelopment |