Distal humeral plating of an intramedullary nail periprosthetic fracture using a miss-a-nail technique: a case report
The treatment of distal humeral periprosthetic fractures is not widely described in the literature. We present a difficult clinical scenario of a 72-year-old man who sustained a displaced distal humeral periprosthetic fracture about a Polarus Plus intramedullary nail. In this case, stable fixation w...