Cargando…

Pseudo-no-Reflow Phenomenon in Carotid Artery Stenting using FilterWire EX: Successful Recovery by Aspiration Thrombectomy

Distal protection devices such as FilterWire EX have been widely used in carotid artery stenting, however, the large amount of atherothrombotic debris entrapped in the filter could reduce or stop antegrade flow. We present a case of pseudo-no-reflow phenomenon after postdilatation of the stent in a...

Descripción completa

Detalles Bibliográficos
Autores principales: Han, Seung Hwan, Kang, Woong Chol, Ahn, Tae Hoon, Shin, Eak Kyun
Formato: Texto
Lenguaje:English
Publicado: The Korean Academy of Medical Sciences 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2752787/
https://www.ncbi.nlm.nih.gov/pubmed/19795002
http://dx.doi.org/10.3346/jkms.2009.24.5.967