A Stability-Indicating High Performance Liquid Chromatographic Method for the Determination of Diacerein in Capsules

A stability-indicating HPLC method was developed and validated for the quantitative determination of diacerein in capsule dosage forms. An isocratic separation was achieved using a perfectsil target ODS-3, 250×4.6 mm i.d., 5 µm particle size columns with a flow rate of 1 ml/min and using a UV detect...

Descripción completa

Detalles Bibliográficos
Autores principales: Rao, Janhavi, Chauhan, Kanchan, Mahadik, K. R., Kadam, S. S.
Formato: Texto
Lenguaje:English
Publicado: Medknow Publications 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2810043/
https://www.ncbi.nlm.nih.gov/pubmed/20177451
http://dx.doi.org/10.4103/0250-474X.51946