Epidural cement leakage through pedicle violation after balloon kyphoplasty causing paraparesis in osteoporotic vertebral compression fractures - a report of two cases

Kyphoplasty is advantageous over vertebroplasty in terms of better kyphosis correction and diminished risk of cement extravasations. Literature described cement leakage causing neurological injury mainly after vertebroplasty procedure; only a few case reports show cement leakage with kyphoplasty wit...