Dose-Dependent Thresholds of 10-ns Electric Pulse Induced Plasma Membrane Disruption and Cytotoxicity in Multiple Cell Lines

In this study, we determined the LD(50) (50% lethal dose) for cell death, and the ED(50) (50% of cell population staining positive) for propidium (Pr) iodide uptake, and phosphatidylserine (PS) externalization for several commonly studied cell lines (HeLa, Jurkat, U937, CHO-K1, and GH3) exposed to 1...

Descripción completa

Detalles Bibliográficos
Autores principales: Ibey, Bennett L., Roth, Caleb C., Pakhomov, Andrei G., Bernhard, Joshua A., Wilmink, Gerald J., Pakhomova, Olga N.
Formato: Texto
Lenguaje:English
Publicado: Public Library of Science 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3027629/
https://www.ncbi.nlm.nih.gov/pubmed/21390200
http://dx.doi.org/10.1371/journal.pone.0015642
_version_ 1782197147833204736
author Ibey, Bennett L.
Roth, Caleb C.
Pakhomov, Andrei G.
Bernhard, Joshua A.
Wilmink, Gerald J.
Pakhomova, Olga N.
author_facet Ibey, Bennett L.
Roth, Caleb C.
Pakhomov, Andrei G.
Bernhard, Joshua A.
Wilmink, Gerald J.
Pakhomova, Olga N.
author_sort Ibey, Bennett L.
collection PubMed
description In this study, we determined the LD(50) (50% lethal dose) for cell death, and the ED(50) (50% of cell population staining positive) for propidium (Pr) iodide uptake, and phosphatidylserine (PS) externalization for several commonly studied cell lines (HeLa, Jurkat, U937, CHO-K1, and GH3) exposed to 10-ns electric pulses (EP). We found that the LD(50) varied substantially across the cell lines studied, increasing from 51 J/g for Jurkat to 1861 J/g for HeLa. PS externalized at doses equal or lower than that required for death in all cell lines ranging from 51 J/g in Jurkat, to 199 J/g in CHO-K1. Pr uptake occurred at doses lower than required for death in three of the cell lines: 656 J/g for CHO-K1, 634 J/g for HeLa, and 142 J/g for GH3. Both Jurkat and U937 had a LD(50) lower than the ED(50) for Pr uptake at 780 J/g and 1274 J/g, respectively. The mechanism responsible for these differences was explored by evaluating cell size, calcium concentration in the exposure medium, and effect of trypsin treatment prior to exposure. None of the studied parameters correlated with the observed results suggesting that cellular susceptibility to injury and death by 10-ns EP was largely determined by cell physiology. In contrast to previous studies, our findings suggest that permeabilization of internal membranes may not necessarily be responsible for cell death by 10-ns EP. Additionally, a mixture of Jurkat and HeLa cells was exposed to 10-ns EP at a dose of 280 J/g. Death was observed only in Jurkat cells suggesting that 10-ns EP may selectively kill cells within a heterogeneous tissue.
format Text
id pubmed-3027629
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-30276292011-03-09 Dose-Dependent Thresholds of 10-ns Electric Pulse Induced Plasma Membrane Disruption and Cytotoxicity in Multiple Cell Lines Ibey, Bennett L. Roth, Caleb C. Pakhomov, Andrei G. Bernhard, Joshua A. Wilmink, Gerald J. Pakhomova, Olga N. PLoS One Research Article In this study, we determined the LD(50) (50% lethal dose) for cell death, and the ED(50) (50% of cell population staining positive) for propidium (Pr) iodide uptake, and phosphatidylserine (PS) externalization for several commonly studied cell lines (HeLa, Jurkat, U937, CHO-K1, and GH3) exposed to 10-ns electric pulses (EP). We found that the LD(50) varied substantially across the cell lines studied, increasing from 51 J/g for Jurkat to 1861 J/g for HeLa. PS externalized at doses equal or lower than that required for death in all cell lines ranging from 51 J/g in Jurkat, to 199 J/g in CHO-K1. Pr uptake occurred at doses lower than required for death in three of the cell lines: 656 J/g for CHO-K1, 634 J/g for HeLa, and 142 J/g for GH3. Both Jurkat and U937 had a LD(50) lower than the ED(50) for Pr uptake at 780 J/g and 1274 J/g, respectively. The mechanism responsible for these differences was explored by evaluating cell size, calcium concentration in the exposure medium, and effect of trypsin treatment prior to exposure. None of the studied parameters correlated with the observed results suggesting that cellular susceptibility to injury and death by 10-ns EP was largely determined by cell physiology. In contrast to previous studies, our findings suggest that permeabilization of internal membranes may not necessarily be responsible for cell death by 10-ns EP. Additionally, a mixture of Jurkat and HeLa cells was exposed to 10-ns EP at a dose of 280 J/g. Death was observed only in Jurkat cells suggesting that 10-ns EP may selectively kill cells within a heterogeneous tissue. Public Library of Science 2011-01-26 /pmc/articles/PMC3027629/ /pubmed/21390200 http://dx.doi.org/10.1371/journal.pone.0015642 Text en This is an open-access article distributed under the terms of the Creative Commons Public Domain declaration which stipulates that, once placed in the public domain, this work may be freely reproduced, distributed, transmitted, modified, built upon, or otherwise used by anyone for any lawful purpose. https://creativecommons.org/publicdomain/zero/1.0/ This is an open-access article distributed under the terms of the Creative Commons Public Domain declaration, which stipulates that, once placed in the public domain, this work may be freely reproduced, distributed, transmitted, modified, built upon, or otherwise used by anyone for any lawful purpose.
spellingShingle Research Article
Ibey, Bennett L.
Roth, Caleb C.
Pakhomov, Andrei G.
Bernhard, Joshua A.
Wilmink, Gerald J.
Pakhomova, Olga N.
Dose-Dependent Thresholds of 10-ns Electric Pulse Induced Plasma Membrane Disruption and Cytotoxicity in Multiple Cell Lines
title Dose-Dependent Thresholds of 10-ns Electric Pulse Induced Plasma Membrane Disruption and Cytotoxicity in Multiple Cell Lines
title_full Dose-Dependent Thresholds of 10-ns Electric Pulse Induced Plasma Membrane Disruption and Cytotoxicity in Multiple Cell Lines
title_fullStr Dose-Dependent Thresholds of 10-ns Electric Pulse Induced Plasma Membrane Disruption and Cytotoxicity in Multiple Cell Lines
title_full_unstemmed Dose-Dependent Thresholds of 10-ns Electric Pulse Induced Plasma Membrane Disruption and Cytotoxicity in Multiple Cell Lines
title_short Dose-Dependent Thresholds of 10-ns Electric Pulse Induced Plasma Membrane Disruption and Cytotoxicity in Multiple Cell Lines
title_sort dose-dependent thresholds of 10-ns electric pulse induced plasma membrane disruption and cytotoxicity in multiple cell lines
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3027629/
https://www.ncbi.nlm.nih.gov/pubmed/21390200
http://dx.doi.org/10.1371/journal.pone.0015642
work_keys_str_mv AT ibeybennettl dosedependentthresholdsof10nselectricpulseinducedplasmamembranedisruptionandcytotoxicityinmultiplecelllines
AT rothcalebc dosedependentthresholdsof10nselectricpulseinducedplasmamembranedisruptionandcytotoxicityinmultiplecelllines
AT pakhomovandreig dosedependentthresholdsof10nselectricpulseinducedplasmamembranedisruptionandcytotoxicityinmultiplecelllines
AT bernhardjoshuaa dosedependentthresholdsof10nselectricpulseinducedplasmamembranedisruptionandcytotoxicityinmultiplecelllines
AT wilminkgeraldj dosedependentthresholdsof10nselectricpulseinducedplasmamembranedisruptionandcytotoxicityinmultiplecelllines
AT pakhomovaolgan dosedependentthresholdsof10nselectricpulseinducedplasmamembranedisruptionandcytotoxicityinmultiplecelllines