Cargando…

Spectral counting assessment of protein dynamic range in cerebrospinal fluid following depletion with plasma-designed immunoaffinity columns

BACKGROUND: In cerebrospinal fluid (CSF), which is a rich source of biomarkers for neurological diseases, identification of biomarkers requires methods that allow reproducible detection of low abundance proteins. It is therefore crucial to decrease dynamic range and improve assessment of protein abu...

Descripción completa

Detalles Bibliográficos
Autores principales: Borg, Jacques, Campos, Alex, Diema, Claudio, Omeñaca, Núria, de Oliveira, Eliandre, Guinovart, Joan, Vilaseca, Marta
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3167203/
https://www.ncbi.nlm.nih.gov/pubmed/21906361
http://dx.doi.org/10.1186/1559-0275-8-6
_version_ 1782211230634606592
author Borg, Jacques
Campos, Alex
Diema, Claudio
Omeñaca, Núria
de Oliveira, Eliandre
Guinovart, Joan
Vilaseca, Marta
author_facet Borg, Jacques
Campos, Alex
Diema, Claudio
Omeñaca, Núria
de Oliveira, Eliandre
Guinovart, Joan
Vilaseca, Marta
author_sort Borg, Jacques
collection PubMed
description BACKGROUND: In cerebrospinal fluid (CSF), which is a rich source of biomarkers for neurological diseases, identification of biomarkers requires methods that allow reproducible detection of low abundance proteins. It is therefore crucial to decrease dynamic range and improve assessment of protein abundance. RESULTS: We applied LC-MS/MS to compare the performance of two CSF enrichment techniques that immunodeplete either albumin alone (IgYHSA) or 14 high-abundance proteins (IgY14). In order to estimate dynamic range of proteins identified, we measured protein abundance with APEX spectral counting method. Both immunodepletion methods improved the number of low-abundance proteins detected (3-fold for IgYHSA, 4-fold for IgY14). The 10 most abundant proteins following immunodepletion accounted for 41% (IgY14) and 46% (IgYHSA) of CSF protein content, whereas they accounted for 64% in non-depleted samples, thus demonstrating significant enrichment of low-abundance proteins. Defined proteomics experiment metrics showed overall good reproducibility of the two immunodepletion methods and MS analysis. Moreover, offline peptide fractionation in IgYHSA sample allowed a 4-fold increase of proteins identified (520 vs. 131 without fractionation), without hindering reproducibility. CONCLUSIONS: The novelty of this study was to show the advantages and drawbacks of these methods side-to-side. Taking into account the improved detection and potential loss of non-target proteins following extensive immunodepletion, it is concluded that both depletion methods combined with spectral counting may be of interest before further fractionation, when searching for CSF biomarkers. According to the reliable identification and quantitation obtained with APEX algorithm, it may be considered as a cheap and quick alternative to study sample proteomic content.
format Online
Article
Text
id pubmed-3167203
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Springer
record_format MEDLINE/PubMed
spelling pubmed-31672032011-09-06 Spectral counting assessment of protein dynamic range in cerebrospinal fluid following depletion with plasma-designed immunoaffinity columns Borg, Jacques Campos, Alex Diema, Claudio Omeñaca, Núria de Oliveira, Eliandre Guinovart, Joan Vilaseca, Marta Clin Proteomics Research BACKGROUND: In cerebrospinal fluid (CSF), which is a rich source of biomarkers for neurological diseases, identification of biomarkers requires methods that allow reproducible detection of low abundance proteins. It is therefore crucial to decrease dynamic range and improve assessment of protein abundance. RESULTS: We applied LC-MS/MS to compare the performance of two CSF enrichment techniques that immunodeplete either albumin alone (IgYHSA) or 14 high-abundance proteins (IgY14). In order to estimate dynamic range of proteins identified, we measured protein abundance with APEX spectral counting method. Both immunodepletion methods improved the number of low-abundance proteins detected (3-fold for IgYHSA, 4-fold for IgY14). The 10 most abundant proteins following immunodepletion accounted for 41% (IgY14) and 46% (IgYHSA) of CSF protein content, whereas they accounted for 64% in non-depleted samples, thus demonstrating significant enrichment of low-abundance proteins. Defined proteomics experiment metrics showed overall good reproducibility of the two immunodepletion methods and MS analysis. Moreover, offline peptide fractionation in IgYHSA sample allowed a 4-fold increase of proteins identified (520 vs. 131 without fractionation), without hindering reproducibility. CONCLUSIONS: The novelty of this study was to show the advantages and drawbacks of these methods side-to-side. Taking into account the improved detection and potential loss of non-target proteins following extensive immunodepletion, it is concluded that both depletion methods combined with spectral counting may be of interest before further fractionation, when searching for CSF biomarkers. According to the reliable identification and quantitation obtained with APEX algorithm, it may be considered as a cheap and quick alternative to study sample proteomic content. Springer 2011-06-03 /pmc/articles/PMC3167203/ /pubmed/21906361 http://dx.doi.org/10.1186/1559-0275-8-6 Text en Copyright ©2011 Borg et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Borg, Jacques
Campos, Alex
Diema, Claudio
Omeñaca, Núria
de Oliveira, Eliandre
Guinovart, Joan
Vilaseca, Marta
Spectral counting assessment of protein dynamic range in cerebrospinal fluid following depletion with plasma-designed immunoaffinity columns
title Spectral counting assessment of protein dynamic range in cerebrospinal fluid following depletion with plasma-designed immunoaffinity columns
title_full Spectral counting assessment of protein dynamic range in cerebrospinal fluid following depletion with plasma-designed immunoaffinity columns
title_fullStr Spectral counting assessment of protein dynamic range in cerebrospinal fluid following depletion with plasma-designed immunoaffinity columns
title_full_unstemmed Spectral counting assessment of protein dynamic range in cerebrospinal fluid following depletion with plasma-designed immunoaffinity columns
title_short Spectral counting assessment of protein dynamic range in cerebrospinal fluid following depletion with plasma-designed immunoaffinity columns
title_sort spectral counting assessment of protein dynamic range in cerebrospinal fluid following depletion with plasma-designed immunoaffinity columns
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3167203/
https://www.ncbi.nlm.nih.gov/pubmed/21906361
http://dx.doi.org/10.1186/1559-0275-8-6
work_keys_str_mv AT borgjacques spectralcountingassessmentofproteindynamicrangeincerebrospinalfluidfollowingdepletionwithplasmadesignedimmunoaffinitycolumns
AT camposalex spectralcountingassessmentofproteindynamicrangeincerebrospinalfluidfollowingdepletionwithplasmadesignedimmunoaffinitycolumns
AT diemaclaudio spectralcountingassessmentofproteindynamicrangeincerebrospinalfluidfollowingdepletionwithplasmadesignedimmunoaffinitycolumns
AT omenacanuria spectralcountingassessmentofproteindynamicrangeincerebrospinalfluidfollowingdepletionwithplasmadesignedimmunoaffinitycolumns
AT deoliveiraeliandre spectralcountingassessmentofproteindynamicrangeincerebrospinalfluidfollowingdepletionwithplasmadesignedimmunoaffinitycolumns
AT guinovartjoan spectralcountingassessmentofproteindynamicrangeincerebrospinalfluidfollowingdepletionwithplasmadesignedimmunoaffinitycolumns
AT vilasecamarta spectralcountingassessmentofproteindynamicrangeincerebrospinalfluidfollowingdepletionwithplasmadesignedimmunoaffinitycolumns