Cellular Imaging Using Equivalent Cross-Relaxation Rate Technique in Rabbit VX-2 Tumor Model

PURPOSE: Equivalent cross-relaxation rate (ECR) imaging (ECRI) is a measurement technique that can be used to quantitatively evaluate changes in structural organization and cellular density by MRI. The aim of this study was to evaluate the correlation between the ECR value and cellular density in th...

Descripción completa

Detalles Bibliográficos
Autores principales: Nishiofuku, Hideyuki, Matsushima, Shigeru, Taguchi, Osamu, Inaba, Yoshitaka, Yamaura, Hidekazu, Sato, Yozo, Tanaka, Toshihiro, Kichikawa, Kimihiko
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Libertas Academica 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3169351/
https://www.ncbi.nlm.nih.gov/pubmed/21918597