Validation of image segmentation by estimating rater bias and variance

The accuracy and precision of segmentations of medical images has been difficult to quantify in the absence of a ‘ground truth’ or reference standard segmentation for clinical data. Although physical or digital phantoms can help by providing a reference standard, they do not allow the reproduction o...

Descripción completa

Detalles Bibliográficos
Autores principales: Warfield, Simon K., Zou, Kelly H., Wells, William M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3227147/
https://www.ncbi.nlm.nih.gov/pubmed/18407896