Coronary Artery Perforation and Regrowth of a Side Branch Occluded by a Polytetrafluoroethylene-Covered Stent Implantation

Stenting of the right coronary artery stenosis caused coronary perforation and profound dye (blood) extravasation in a 69-year-old female patient. Instantaneous balloon inflation followed by implantation of a polytetrafluoroethylene- (PTFE-)covered stent sealed the coronary perforation, restored the...