Cargando…

Meniscal sutures: biomechanical study of “mulberry” and horizontal loop techniques

BACKGROUND: This in vitro biomechanical study tested the pullout strength of meniscal repair in human menisci using two different biodegradable suture techniques: the “mulberry” and the horizontal loop. MATERIALS AND METHODS: Fifty-five human menisci were used, to which a longitudinal tear of 1.5 cm...

Descripción completa

Detalles Bibliográficos
Autores principales: Fantasia, Fabiano, Potalivo, Gabriele, Placella, Giacomo, Fantasia, Luigi, Cerulli, Giuliano
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3284664/
https://www.ncbi.nlm.nih.gov/pubmed/22190242
http://dx.doi.org/10.1007/s10195-011-0162-y