Meniscal sutures: biomechanical study of “mulberry” and horizontal loop techniques

BACKGROUND: This in vitro biomechanical study tested the pullout strength of meniscal repair in human menisci using two different biodegradable suture techniques: the “mulberry” and the horizontal loop. MATERIALS AND METHODS: Fifty-five human menisci were used, to which a longitudinal tear of 1.5 cm...