Development of a Three Dimensional Neural Sensing Device by a Stacking Method

This study reports a new stacking method for assembling a 3-D microprobe array. To date, 3-D array structures have usually been assembled with vertical spacers, snap fasteners and a supporting platform. Such methods have achieved 3-D structures but suffer from complex assembly steps, vertical interc...

Descripción completa

Detalles Bibliográficos
Autores principales: Chang, Chih-Wei, Chiou, Jin-Chern
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3292117/
https://www.ncbi.nlm.nih.gov/pubmed/22399878
http://dx.doi.org/10.3390/s100504238
_version_ 1782225236515618816
author Chang, Chih-Wei
Chiou, Jin-Chern
author_facet Chang, Chih-Wei
Chiou, Jin-Chern
author_sort Chang, Chih-Wei
collection PubMed
description This study reports a new stacking method for assembling a 3-D microprobe array. To date, 3-D array structures have usually been assembled with vertical spacers, snap fasteners and a supporting platform. Such methods have achieved 3-D structures but suffer from complex assembly steps, vertical interconnection for 3-D signal transmission, low structure strength and large implantable opening. By applying the proposed stacking method, the previous techniques could be replaced by 2-D wire bonding. In this way, supporting platforms with slots and vertical spacers were no longer needed. Furthermore, ASIC chips can be substituted for the spacers in the stacked arrays to achieve system integration, design flexibility and volume usage efficiency. To avoid overflow of the adhesive fluid during assembly, an anti-overflow design which made use of capillary action force was applied in the stacking method as well. Moreover, presented stacking procedure consumes only 35 minutes in average for a 4 × 4 3-D microprobe array without requiring other specially made assembly tools. To summarize, the advantages of the proposed stacking method for 3-D array assembly include simplified assembly process, high structure strength, smaller opening area and integration ability with active circuits. This stacking assembly technique allows an alternative method to create 3-D structures from planar components.
format Online
Article
Text
id pubmed-3292117
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-32921172012-03-07 Development of a Three Dimensional Neural Sensing Device by a Stacking Method Chang, Chih-Wei Chiou, Jin-Chern Sensors (Basel) Article This study reports a new stacking method for assembling a 3-D microprobe array. To date, 3-D array structures have usually been assembled with vertical spacers, snap fasteners and a supporting platform. Such methods have achieved 3-D structures but suffer from complex assembly steps, vertical interconnection for 3-D signal transmission, low structure strength and large implantable opening. By applying the proposed stacking method, the previous techniques could be replaced by 2-D wire bonding. In this way, supporting platforms with slots and vertical spacers were no longer needed. Furthermore, ASIC chips can be substituted for the spacers in the stacked arrays to achieve system integration, design flexibility and volume usage efficiency. To avoid overflow of the adhesive fluid during assembly, an anti-overflow design which made use of capillary action force was applied in the stacking method as well. Moreover, presented stacking procedure consumes only 35 minutes in average for a 4 × 4 3-D microprobe array without requiring other specially made assembly tools. To summarize, the advantages of the proposed stacking method for 3-D array assembly include simplified assembly process, high structure strength, smaller opening area and integration ability with active circuits. This stacking assembly technique allows an alternative method to create 3-D structures from planar components. Molecular Diversity Preservation International (MDPI) 2010-04-28 /pmc/articles/PMC3292117/ /pubmed/22399878 http://dx.doi.org/10.3390/s100504238 Text en © 2010 by the authors; licensee MDPI, Basel, Switzerland. This article is an open-access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Chang, Chih-Wei
Chiou, Jin-Chern
Development of a Three Dimensional Neural Sensing Device by a Stacking Method
title Development of a Three Dimensional Neural Sensing Device by a Stacking Method
title_full Development of a Three Dimensional Neural Sensing Device by a Stacking Method
title_fullStr Development of a Three Dimensional Neural Sensing Device by a Stacking Method
title_full_unstemmed Development of a Three Dimensional Neural Sensing Device by a Stacking Method
title_short Development of a Three Dimensional Neural Sensing Device by a Stacking Method
title_sort development of a three dimensional neural sensing device by a stacking method
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3292117/
https://www.ncbi.nlm.nih.gov/pubmed/22399878
http://dx.doi.org/10.3390/s100504238
work_keys_str_mv AT changchihwei developmentofathreedimensionalneuralsensingdevicebyastackingmethod
AT chioujinchern developmentofathreedimensionalneuralsensingdevicebyastackingmethod