Cargando…
Novel standards in the measurement of rat insulin granules combining electron microscopy, high-content image analysis and in silico modelling
AIMS/HYPOTHESIS: Knowledge of number, size and content of insulin secretory granules is pivotal for understanding the physiology of pancreatic beta cells. Here we re-evaluated key structural features of rat beta cells, including insulin granule size, number and distribution as well as cell size. MET...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer-Verlag
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3296007/ https://www.ncbi.nlm.nih.gov/pubmed/22252472 http://dx.doi.org/10.1007/s00125-011-2438-4 |
_version_ | 1782225661858938880 |
---|---|
author | Fava, E. Dehghany, J. Ouwendijk, J. Müller, A. Niederlein, A. Verkade, P. Meyer-Hermann, M. Solimena, M. |
author_facet | Fava, E. Dehghany, J. Ouwendijk, J. Müller, A. Niederlein, A. Verkade, P. Meyer-Hermann, M. Solimena, M. |
author_sort | Fava, E. |
collection | PubMed |
description | AIMS/HYPOTHESIS: Knowledge of number, size and content of insulin secretory granules is pivotal for understanding the physiology of pancreatic beta cells. Here we re-evaluated key structural features of rat beta cells, including insulin granule size, number and distribution as well as cell size. METHODS: Electron micrographs of rat beta cells fixed either chemically or by high-pressure freezing were compared using a high-content analysis approach. These data were used to develop three-dimensional in silico beta cell models, the slicing of which would reproduce the experimental datasets. RESULTS: As previously reported, chemically fixed insulin secretory granules appeared as hollow spheres with a mean diameter of ∼350 nm. Remarkably, most granules fixed by high-pressure freezing lacked the characteristic halo between the dense core and the limiting membrane and were smaller than their chemically fixed counterparts. Based on our analyses, we conclude that the mean diameter of rat insulin secretory granules is 243 nm, corresponding to a surface area of 0.19 μm(2). Rat beta cells have a mean volume of 763 μm(3) and contain 5,000–6,000 granules. CONCLUSIONS/INTERPRETATION: A major reason for the lower mean granule number/rat beta cell relative to previous accounts is a reduced estimation of the mean beta cell volume. These findings imply that each granule contains about twofold more insulin, while its exocytosis increases membrane capacitance about twofold less than assumed previously. Our integrated approach defines new standards for quantitative image analysis of beta cells and could be applied to other cellular systems. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s00125-011-2438-4) contains peer-reviewed but unedited supplementary material, which is available to authorised users. |
format | Online Article Text |
id | pubmed-3296007 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Springer-Verlag |
record_format | MEDLINE/PubMed |
spelling | pubmed-32960072012-03-21 Novel standards in the measurement of rat insulin granules combining electron microscopy, high-content image analysis and in silico modelling Fava, E. Dehghany, J. Ouwendijk, J. Müller, A. Niederlein, A. Verkade, P. Meyer-Hermann, M. Solimena, M. Diabetologia Article AIMS/HYPOTHESIS: Knowledge of number, size and content of insulin secretory granules is pivotal for understanding the physiology of pancreatic beta cells. Here we re-evaluated key structural features of rat beta cells, including insulin granule size, number and distribution as well as cell size. METHODS: Electron micrographs of rat beta cells fixed either chemically or by high-pressure freezing were compared using a high-content analysis approach. These data were used to develop three-dimensional in silico beta cell models, the slicing of which would reproduce the experimental datasets. RESULTS: As previously reported, chemically fixed insulin secretory granules appeared as hollow spheres with a mean diameter of ∼350 nm. Remarkably, most granules fixed by high-pressure freezing lacked the characteristic halo between the dense core and the limiting membrane and were smaller than their chemically fixed counterparts. Based on our analyses, we conclude that the mean diameter of rat insulin secretory granules is 243 nm, corresponding to a surface area of 0.19 μm(2). Rat beta cells have a mean volume of 763 μm(3) and contain 5,000–6,000 granules. CONCLUSIONS/INTERPRETATION: A major reason for the lower mean granule number/rat beta cell relative to previous accounts is a reduced estimation of the mean beta cell volume. These findings imply that each granule contains about twofold more insulin, while its exocytosis increases membrane capacitance about twofold less than assumed previously. Our integrated approach defines new standards for quantitative image analysis of beta cells and could be applied to other cellular systems. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s00125-011-2438-4) contains peer-reviewed but unedited supplementary material, which is available to authorised users. Springer-Verlag 2012-01-18 2012 /pmc/articles/PMC3296007/ /pubmed/22252472 http://dx.doi.org/10.1007/s00125-011-2438-4 Text en © The Author(s) 2012 https://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited. |
spellingShingle | Article Fava, E. Dehghany, J. Ouwendijk, J. Müller, A. Niederlein, A. Verkade, P. Meyer-Hermann, M. Solimena, M. Novel standards in the measurement of rat insulin granules combining electron microscopy, high-content image analysis and in silico modelling |
title | Novel standards in the measurement of rat insulin granules combining electron microscopy, high-content image analysis and in silico modelling |
title_full | Novel standards in the measurement of rat insulin granules combining electron microscopy, high-content image analysis and in silico modelling |
title_fullStr | Novel standards in the measurement of rat insulin granules combining electron microscopy, high-content image analysis and in silico modelling |
title_full_unstemmed | Novel standards in the measurement of rat insulin granules combining electron microscopy, high-content image analysis and in silico modelling |
title_short | Novel standards in the measurement of rat insulin granules combining electron microscopy, high-content image analysis and in silico modelling |
title_sort | novel standards in the measurement of rat insulin granules combining electron microscopy, high-content image analysis and in silico modelling |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3296007/ https://www.ncbi.nlm.nih.gov/pubmed/22252472 http://dx.doi.org/10.1007/s00125-011-2438-4 |
work_keys_str_mv | AT favae novelstandardsinthemeasurementofratinsulingranulescombiningelectronmicroscopyhighcontentimageanalysisandinsilicomodelling AT dehghanyj novelstandardsinthemeasurementofratinsulingranulescombiningelectronmicroscopyhighcontentimageanalysisandinsilicomodelling AT ouwendijkj novelstandardsinthemeasurementofratinsulingranulescombiningelectronmicroscopyhighcontentimageanalysisandinsilicomodelling AT mullera novelstandardsinthemeasurementofratinsulingranulescombiningelectronmicroscopyhighcontentimageanalysisandinsilicomodelling AT niederleina novelstandardsinthemeasurementofratinsulingranulescombiningelectronmicroscopyhighcontentimageanalysisandinsilicomodelling AT verkadep novelstandardsinthemeasurementofratinsulingranulescombiningelectronmicroscopyhighcontentimageanalysisandinsilicomodelling AT meyerhermannm novelstandardsinthemeasurementofratinsulingranulescombiningelectronmicroscopyhighcontentimageanalysisandinsilicomodelling AT solimenam novelstandardsinthemeasurementofratinsulingranulescombiningelectronmicroscopyhighcontentimageanalysisandinsilicomodelling |