Reliability and Usefulness of the Pressure Pain Threshold Measurement in Patients with Myofascial Pain
OBJECTIVE: To assess the usefulness of a pressure algometer to measure pressure pain threshold (PPT) for diagnosis of myofascial pain syndrome (MPS) in the upper extremity and trunk muscles. METHOD: A group of 221 desk workers complaining of upper body pain participated in this study. Five physiatri...
Autores principales: | Park, Giburm, Kim, Chan Woo, Park, Si Bog, Kim, Mi Jung, Jang, Seong Ho |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Academy of Rehabilitation Medicine
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3309218/ https://www.ncbi.nlm.nih.gov/pubmed/22506152 http://dx.doi.org/10.5535/arm.2011.35.3.412 |
Ejemplares similares
-
A novel metric of reliability in pressure pain threshold measurement
por: Liew, Bernard, et al.
Publicado: (2021) -
Serum inflammatory and oxidative stress biomarkers levels are associated with pain intensity, pressure pain threshold and quality of life in myofascial pain syndrome
por: Shakouri, Seyed Kazem, et al.
Publicado: (2020) -
Assessment of pressure pain thresholds in collisions with collaborative robots
por: Park, Moon Young, et al.
Publicado: (2019) -
Characteristics of Myofascial Pain Syndrome of the Infraspinatus Muscle
por: Kwon, Junbeom, et al.
Publicado: (2017) -
Reliability and responsiveness of algometry for measuring pressure pain
threshold in patients with knee osteoarthritis
por: Mutlu, Ebru Kaya, et al.
Publicado: (2015)