Development of an Integrated Chip for Automatic Tracking and Positioning Manipulation for Single Cell Lysis

This study adopted a microelectromechanical fabrication process to design a chip integrated with electroosmotic flow and dielectrophoresis force for single cell lysis. Human histiocytic lymphoma U937 cells were driven rapidly by electroosmotic flow and precisely moved to a specific area for cell lys...