Cargando…

Unintended Cannulation of the Subclavian Artery in a 65-Year-Old-Female for Temporary Hemodialysis Vascular Access: Management and Prevention

Ultrasound-guided cannulation of a large-bore catheter into the internal jugular vein was performed to provide temporary hemodialysis vascular access for uremia in a 65-yr-old woman with acute renal failure and sepsis superimposed on chronic renal failure. Despite the absence of any clinical evidenc...

Descripción completa

Detalles Bibliográficos
Autores principales: Choi, Jeong-Im, Cho, Sung-Gun, Yi, Joo-Hark, Han, Sang-Woong, Kim, Ho-Jung
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Academy of Medical Sciences 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3468767/
https://www.ncbi.nlm.nih.gov/pubmed/23091328
http://dx.doi.org/10.3346/jkms.2012.27.10.1265