Cargando…
Charge movement in gating-locked HCN channels reveals weak coupling of voltage sensors and gate
HCN (hyperpolarization-activated cyclic nucleotide gated) pacemaker channels have an architecture similar to that of voltage-gated K(+) channels, but they open with the opposite voltage dependence. HCN channels use essentially the same positively charged voltage sensors and intracellular activation...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Rockefeller University Press
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3483112/ https://www.ncbi.nlm.nih.gov/pubmed/23071265 http://dx.doi.org/10.1085/jgp.201210850 |
_version_ | 1782247944113618944 |
---|---|
author | Ryu, Sujung Yellen, Gary |
author_facet | Ryu, Sujung Yellen, Gary |
author_sort | Ryu, Sujung |
collection | PubMed |
description | HCN (hyperpolarization-activated cyclic nucleotide gated) pacemaker channels have an architecture similar to that of voltage-gated K(+) channels, but they open with the opposite voltage dependence. HCN channels use essentially the same positively charged voltage sensors and intracellular activation gates as K(+) channels, but apparently these two components are coupled differently. In this study, we examine the energetics of coupling between the voltage sensor and the pore by using cysteine mutant channels for which low concentrations of Cd(2+) ions freeze the open–closed gating machinery but still allow the sensors to move. We were able to lock mutant channels either into open or into closed states by the application of Cd(2+) and measure the effect on voltage sensor movement. Cd(2+) did not immobilize the gating charge, as expected for strict coupling, but rather it produced shifts in the voltage dependence of voltage sensor charge movement, consistent with its effect of confining transitions to either closed or open states. From the magnitude of the Cd(2+)-induced shifts, we estimate that each voltage sensor produces a roughly three- to sevenfold effect on the open–closed equilibrium, corresponding to a coupling energy of ∼1.3–2 kT per sensor. Such coupling is not only opposite in sign to the coupling in K(+) channels, but also much weaker. |
format | Online Article Text |
id | pubmed-3483112 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | The Rockefeller University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-34831122013-05-01 Charge movement in gating-locked HCN channels reveals weak coupling of voltage sensors and gate Ryu, Sujung Yellen, Gary J Gen Physiol Article HCN (hyperpolarization-activated cyclic nucleotide gated) pacemaker channels have an architecture similar to that of voltage-gated K(+) channels, but they open with the opposite voltage dependence. HCN channels use essentially the same positively charged voltage sensors and intracellular activation gates as K(+) channels, but apparently these two components are coupled differently. In this study, we examine the energetics of coupling between the voltage sensor and the pore by using cysteine mutant channels for which low concentrations of Cd(2+) ions freeze the open–closed gating machinery but still allow the sensors to move. We were able to lock mutant channels either into open or into closed states by the application of Cd(2+) and measure the effect on voltage sensor movement. Cd(2+) did not immobilize the gating charge, as expected for strict coupling, but rather it produced shifts in the voltage dependence of voltage sensor charge movement, consistent with its effect of confining transitions to either closed or open states. From the magnitude of the Cd(2+)-induced shifts, we estimate that each voltage sensor produces a roughly three- to sevenfold effect on the open–closed equilibrium, corresponding to a coupling energy of ∼1.3–2 kT per sensor. Such coupling is not only opposite in sign to the coupling in K(+) channels, but also much weaker. The Rockefeller University Press 2012-11 /pmc/articles/PMC3483112/ /pubmed/23071265 http://dx.doi.org/10.1085/jgp.201210850 Text en © 2012 Ryu and Yellen This article is distributed under the terms of an Attribution–Noncommercial–Share Alike–No Mirror Sites license for the first six months after the publication date (see http://www.rupress.org/terms). After six months it is available under a Creative Commons License (Attribution–Noncommercial–Share Alike 3.0 Unported license, as described at http://creativecommons.org/licenses/by-nc-sa/3.0/). |
spellingShingle | Article Ryu, Sujung Yellen, Gary Charge movement in gating-locked HCN channels reveals weak coupling of voltage sensors and gate |
title | Charge movement in gating-locked HCN channels reveals weak coupling of voltage sensors and gate |
title_full | Charge movement in gating-locked HCN channels reveals weak coupling of voltage sensors and gate |
title_fullStr | Charge movement in gating-locked HCN channels reveals weak coupling of voltage sensors and gate |
title_full_unstemmed | Charge movement in gating-locked HCN channels reveals weak coupling of voltage sensors and gate |
title_short | Charge movement in gating-locked HCN channels reveals weak coupling of voltage sensors and gate |
title_sort | charge movement in gating-locked hcn channels reveals weak coupling of voltage sensors and gate |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3483112/ https://www.ncbi.nlm.nih.gov/pubmed/23071265 http://dx.doi.org/10.1085/jgp.201210850 |
work_keys_str_mv | AT ryusujung chargemovementingatinglockedhcnchannelsrevealsweakcouplingofvoltagesensorsandgate AT yellengary chargemovementingatinglockedhcnchannelsrevealsweakcouplingofvoltagesensorsandgate |