Cargando…

Application of a dummy eye shield for electron treatment planning

Metallic eye shields have been widely used for near-eye treatments to protect critical regions, but have never been incorporated into treatment plans because of the unwanted appearance of the metal artifacts on CT images. The purpose of this work was to test the use of an acrylic dummy eye shield as...

Descripción completa

Detalles Bibliográficos
Autores principales: Kang, Sei-Kwon, Park, Soah, Hwang, Taejin, Cheong, Kwang-Ho, Han, Taejin, Kim, Haeyoung, Lee, Me-Yeon, Kim, Kyoung Ju, Oh, Do Hoon, Bae, Hoonsik
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3534269/
https://www.ncbi.nlm.nih.gov/pubmed/22915776
http://dx.doi.org/10.1093/jrr/rrs067