Cargando…

An in vitro liver model - assessing oxidative stress and genotoxicity following exposure of hepatocytes to a panel of engineered nanomaterials

BACKGROUND: Following exposure via inhalation, intratracheal instillation or ingestion some nanomaterials (NM) have been shown to translocate to the liver. Since oxidative stress has been implicated as a possible mechanism for NM toxicity this study aimed to investigate the effects of various materi...

Descripción completa

Detalles Bibliográficos
Autores principales: Kermanizadeh, Ali, Gaiser, Birgit K, Hutchison, Gary R, Stone, Vicki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3546021/
https://www.ncbi.nlm.nih.gov/pubmed/22812506
http://dx.doi.org/10.1186/1743-8977-9-28
_version_ 1782255983890792448
author Kermanizadeh, Ali
Gaiser, Birgit K
Hutchison, Gary R
Stone, Vicki
author_facet Kermanizadeh, Ali
Gaiser, Birgit K
Hutchison, Gary R
Stone, Vicki
author_sort Kermanizadeh, Ali
collection PubMed
description BACKGROUND: Following exposure via inhalation, intratracheal instillation or ingestion some nanomaterials (NM) have been shown to translocate to the liver. Since oxidative stress has been implicated as a possible mechanism for NM toxicity this study aimed to investigate the effects of various materials (five titanium dioxide (TiO(2)), two zinc oxide (ZnO), two multi-walled carbon nanotubes (MWCNT) and one silver (Ag) NM) on oxidative responses of C3A cell line as a model for potential detrimental properties of nanomaterials on the liver. RESULTS: We noted a dose dependant decrease in the cellular glutathione content following exposure of the C3A cells to Ag, the ZnO and the MWCNTs. Intracellular ROS levels were also measured and shown to increase significantly following exposure of the C3A to the low toxicity NMs (MWCNT and TiO(2)). The antioxidant Trolox in part prevented the detrimental effect of NMs on cell viability, and decreased the NM induced IL8 production after exposure to all but the Ag particulate. Following 4 hr exposure of the C3A cells to sub-lethal levels of the NMs, the largest amount of DNA damage was induced by two of the TiO(2) samples (7 nm and the positively charged 10 nm particles). CONCLUSIONS: All ten NMs exhibited effects on the hepatocyte cell line that were at least in part ROS/oxidative stress mediated. These effects included mild genotoxicity and IL8 production for all NM except the Ag possibly due to its highly cytotoxic nature.
format Online
Article
Text
id pubmed-3546021
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-35460212013-01-17 An in vitro liver model - assessing oxidative stress and genotoxicity following exposure of hepatocytes to a panel of engineered nanomaterials Kermanizadeh, Ali Gaiser, Birgit K Hutchison, Gary R Stone, Vicki Part Fibre Toxicol Research BACKGROUND: Following exposure via inhalation, intratracheal instillation or ingestion some nanomaterials (NM) have been shown to translocate to the liver. Since oxidative stress has been implicated as a possible mechanism for NM toxicity this study aimed to investigate the effects of various materials (five titanium dioxide (TiO(2)), two zinc oxide (ZnO), two multi-walled carbon nanotubes (MWCNT) and one silver (Ag) NM) on oxidative responses of C3A cell line as a model for potential detrimental properties of nanomaterials on the liver. RESULTS: We noted a dose dependant decrease in the cellular glutathione content following exposure of the C3A cells to Ag, the ZnO and the MWCNTs. Intracellular ROS levels were also measured and shown to increase significantly following exposure of the C3A to the low toxicity NMs (MWCNT and TiO(2)). The antioxidant Trolox in part prevented the detrimental effect of NMs on cell viability, and decreased the NM induced IL8 production after exposure to all but the Ag particulate. Following 4 hr exposure of the C3A cells to sub-lethal levels of the NMs, the largest amount of DNA damage was induced by two of the TiO(2) samples (7 nm and the positively charged 10 nm particles). CONCLUSIONS: All ten NMs exhibited effects on the hepatocyte cell line that were at least in part ROS/oxidative stress mediated. These effects included mild genotoxicity and IL8 production for all NM except the Ag possibly due to its highly cytotoxic nature. BioMed Central 2012-07-19 /pmc/articles/PMC3546021/ /pubmed/22812506 http://dx.doi.org/10.1186/1743-8977-9-28 Text en Copyright ©2012 Kermanizadeh et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Kermanizadeh, Ali
Gaiser, Birgit K
Hutchison, Gary R
Stone, Vicki
An in vitro liver model - assessing oxidative stress and genotoxicity following exposure of hepatocytes to a panel of engineered nanomaterials
title An in vitro liver model - assessing oxidative stress and genotoxicity following exposure of hepatocytes to a panel of engineered nanomaterials
title_full An in vitro liver model - assessing oxidative stress and genotoxicity following exposure of hepatocytes to a panel of engineered nanomaterials
title_fullStr An in vitro liver model - assessing oxidative stress and genotoxicity following exposure of hepatocytes to a panel of engineered nanomaterials
title_full_unstemmed An in vitro liver model - assessing oxidative stress and genotoxicity following exposure of hepatocytes to a panel of engineered nanomaterials
title_short An in vitro liver model - assessing oxidative stress and genotoxicity following exposure of hepatocytes to a panel of engineered nanomaterials
title_sort in vitro liver model - assessing oxidative stress and genotoxicity following exposure of hepatocytes to a panel of engineered nanomaterials
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3546021/
https://www.ncbi.nlm.nih.gov/pubmed/22812506
http://dx.doi.org/10.1186/1743-8977-9-28
work_keys_str_mv AT kermanizadehali aninvitrolivermodelassessingoxidativestressandgenotoxicityfollowingexposureofhepatocytestoapanelofengineerednanomaterials
AT gaiserbirgitk aninvitrolivermodelassessingoxidativestressandgenotoxicityfollowingexposureofhepatocytestoapanelofengineerednanomaterials
AT hutchisongaryr aninvitrolivermodelassessingoxidativestressandgenotoxicityfollowingexposureofhepatocytestoapanelofengineerednanomaterials
AT stonevicki aninvitrolivermodelassessingoxidativestressandgenotoxicityfollowingexposureofhepatocytestoapanelofengineerednanomaterials
AT kermanizadehali invitrolivermodelassessingoxidativestressandgenotoxicityfollowingexposureofhepatocytestoapanelofengineerednanomaterials
AT gaiserbirgitk invitrolivermodelassessingoxidativestressandgenotoxicityfollowingexposureofhepatocytestoapanelofengineerednanomaterials
AT hutchisongaryr invitrolivermodelassessingoxidativestressandgenotoxicityfollowingexposureofhepatocytestoapanelofengineerednanomaterials
AT stonevicki invitrolivermodelassessingoxidativestressandgenotoxicityfollowingexposureofhepatocytestoapanelofengineerednanomaterials