Cargando…

Objective evaluation of plantar hyperhidrosis after sympathectomy

OBJECTIVE: The aim of the present study was to prospectively, randomly, blindly, and objectively investigate how surgery affects plantar sudoresis in patients with palmar and plantar hyperhidrosis over a one-year period using a sudorometer (VapoMeter). METHODS: From February 2007 to May 2009, 40 con...

Descripción completa

Detalles Bibliográficos
Autores principales: Wolosker, Nelson, Ishy, Augusto, Yazbek, Guilherme, de Campos, José Ribas Milanez, Kauffman, Paulo, Puech-Leão, Pedro, Jatene, Fábio Biscegli
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3611758/
https://www.ncbi.nlm.nih.gov/pubmed/23644849
http://dx.doi.org/10.6061/clinics/2013(03)OA05