Cargando…
Validated Densitometric TLC-Method for the Simultaneous Analysis of (R)- and (S)-Citalopram and its Related Substances Using Macrocyclic Antibiotic as a Chiral Selector: Application to the Determination of Enantiomeric Purity of Escitalopram
A novel economic procedure for the simultaneous stereospecific separation and analysis of (R)- and (S)-citalopram and its related substances or impurities has been developed and validated. Chromatography was performed on silica gel 60 F254 plates with acetonitrile: methanol: water (15:2.5:2.5: v/v/v...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Master Publishing Group
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3614854/ https://www.ncbi.nlm.nih.gov/pubmed/23675256 |
Sumario: | A novel economic procedure for the simultaneous stereospecific separation and analysis of (R)- and (S)-citalopram and its related substances or impurities has been developed and validated. Chromatography was performed on silica gel 60 F254 plates with acetonitrile: methanol: water (15:2.5:2.5: v/v/v) as a mobile phase containing 1.5 mM norvancomycin or 2.5 mM vancomycin as a selector at ambient temperature. (R)- and (S)-citalopram enantiomers in presence of its related substances; citalopram citadiol and citalopram N-oxide were well separated with significant Rf values of 0.33 ± 0.02, 0.85 ± 0.02, 0.45 ± 0.02 and 0.22 ± 0.02, respectively. The spots were detected with either iodine vapor, or by use of a UV lamp followed by densitometric measurement at 239 nm. All variables affecting the resolution, such as concentration of chiral selectors, mobile phase system at different temperatures and pH-values were investigated and the conditions were optimized. Calibration plots for analysis of (R)- and (S)-enantiomers were linear in the range of 0.2-16.8 μg/10 μl (R≥0.9994, n=6) with acceptable precision (%RSD<2.0) and accuracy (99.70 ± 0.85% and 99.51 ± 0.61% for (S)-citalopram and escitalopram, respectively). The limit of detection and quantification were 0.08 μg/10 μl and 0.25 μg/10 μl, respectively, for (R)- and (S)-citalopram. The proposed method is simple, selective, and robust and can be applied for quantitative determination of enantiomeric purity of (R)- and (S)-citalopram (escitalopram) as well as the related impurities in drug substances and pharmaceutical preparations. The method can be useful to investigate adulteration of pure isomer with the cheep racemic form. |
---|