Cargando…

A simple and rapid high-performance liquid chromatographic method for determining tobramycin in pharmaceutical formulations by direct UV detection

BACKGROUND: Tobramycin, an aminoglycoside antibiotic, is a polar pharmaceutical compound which lacks a UV absorbing chromophore. Due to the absence of a UV absorbing chromophore and high polar nature of this antibiotic, the analysis of such compounds becomes a major challenge. OBJECTIVE: To overcome...

Descripción completa

Detalles Bibliográficos
Autores principales: Ruckmani, K., Shaikh, Saleem Z., Khalil, Pavne, Muneera, M. S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3658043/
https://www.ncbi.nlm.nih.gov/pubmed/23781441
http://dx.doi.org/10.4103/2229-4708.84455
_version_ 1782270214448087040
author Ruckmani, K.
Shaikh, Saleem Z.
Khalil, Pavne
Muneera, M. S.
author_facet Ruckmani, K.
Shaikh, Saleem Z.
Khalil, Pavne
Muneera, M. S.
author_sort Ruckmani, K.
collection PubMed
description BACKGROUND: Tobramycin, an aminoglycoside antibiotic, is a polar pharmaceutical compound which lacks a UV absorbing chromophore. Due to the absence of a UV absorbing chromophore and high polar nature of this antibiotic, the analysis of such compounds becomes a major challenge. OBJECTIVE: To overcome these problems, a novel method for the determination aminoglycoside tobramycin was developed and validated based on reversed-phase high-performance liquid chromatography (RP-HPLC) with UV detector. MATERIALS AND METHODS: An isocratic mobile phase consists of buffer 0.05 M diammonium hydrogen phosphate, pH adjusted to 10.0 using tetramethyl ammonium hydroxide. Chromatography was carried out at 25°C on a Purosphere RP-8e, 250 mm × 4.6 mm, 5mm. The detection was carried out using variable wavelength UV-Vis detector set at 210 nm. The compounds were eluted isocratically at a steady flow rate of 1.0 mL/min. RESULT AND DISCUSSION: Tobramycin retention time was about 9.0 min with an asymmetry factor of 1.4. A logarithmic calibration curve was obtained from 0.47 to 0.71 mg/mL (r > 0.9998). Within-day %RSD was 0.29 (n = 6, 0.60 mg/mL) and between-day %RSD was 0.54 Specificity/ selectivity experiments revealed the absence of interference from excipients, recovery from spiked samples was between 99.0–100.0 percent. CONCLUSIONS: A HPLC method based on UV detection has been developed and validated for determination of tobramycin from ophthalmic solution. The method is simple, rapid, specific, accurate (error 0.80%), precise (RSD <2.0%) and linear (r2=0.9998). The described method is suitable for routine analysis and quality control of ophthalmic solution containing tobramycin.
format Online
Article
Text
id pubmed-3658043
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-36580432013-06-18 A simple and rapid high-performance liquid chromatographic method for determining tobramycin in pharmaceutical formulations by direct UV detection Ruckmani, K. Shaikh, Saleem Z. Khalil, Pavne Muneera, M. S. Pharm Methods Original Article BACKGROUND: Tobramycin, an aminoglycoside antibiotic, is a polar pharmaceutical compound which lacks a UV absorbing chromophore. Due to the absence of a UV absorbing chromophore and high polar nature of this antibiotic, the analysis of such compounds becomes a major challenge. OBJECTIVE: To overcome these problems, a novel method for the determination aminoglycoside tobramycin was developed and validated based on reversed-phase high-performance liquid chromatography (RP-HPLC) with UV detector. MATERIALS AND METHODS: An isocratic mobile phase consists of buffer 0.05 M diammonium hydrogen phosphate, pH adjusted to 10.0 using tetramethyl ammonium hydroxide. Chromatography was carried out at 25°C on a Purosphere RP-8e, 250 mm × 4.6 mm, 5mm. The detection was carried out using variable wavelength UV-Vis detector set at 210 nm. The compounds were eluted isocratically at a steady flow rate of 1.0 mL/min. RESULT AND DISCUSSION: Tobramycin retention time was about 9.0 min with an asymmetry factor of 1.4. A logarithmic calibration curve was obtained from 0.47 to 0.71 mg/mL (r > 0.9998). Within-day %RSD was 0.29 (n = 6, 0.60 mg/mL) and between-day %RSD was 0.54 Specificity/ selectivity experiments revealed the absence of interference from excipients, recovery from spiked samples was between 99.0–100.0 percent. CONCLUSIONS: A HPLC method based on UV detection has been developed and validated for determination of tobramycin from ophthalmic solution. The method is simple, rapid, specific, accurate (error 0.80%), precise (RSD <2.0%) and linear (r2=0.9998). The described method is suitable for routine analysis and quality control of ophthalmic solution containing tobramycin. Medknow Publications & Media Pvt Ltd 2011 /pmc/articles/PMC3658043/ /pubmed/23781441 http://dx.doi.org/10.4103/2229-4708.84455 Text en Copyright: © Pharmaceutical Methods http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Ruckmani, K.
Shaikh, Saleem Z.
Khalil, Pavne
Muneera, M. S.
A simple and rapid high-performance liquid chromatographic method for determining tobramycin in pharmaceutical formulations by direct UV detection
title A simple and rapid high-performance liquid chromatographic method for determining tobramycin in pharmaceutical formulations by direct UV detection
title_full A simple and rapid high-performance liquid chromatographic method for determining tobramycin in pharmaceutical formulations by direct UV detection
title_fullStr A simple and rapid high-performance liquid chromatographic method for determining tobramycin in pharmaceutical formulations by direct UV detection
title_full_unstemmed A simple and rapid high-performance liquid chromatographic method for determining tobramycin in pharmaceutical formulations by direct UV detection
title_short A simple and rapid high-performance liquid chromatographic method for determining tobramycin in pharmaceutical formulations by direct UV detection
title_sort simple and rapid high-performance liquid chromatographic method for determining tobramycin in pharmaceutical formulations by direct uv detection
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3658043/
https://www.ncbi.nlm.nih.gov/pubmed/23781441
http://dx.doi.org/10.4103/2229-4708.84455
work_keys_str_mv AT ruckmanik asimpleandrapidhighperformanceliquidchromatographicmethodfordeterminingtobramycininpharmaceuticalformulationsbydirectuvdetection
AT shaikhsaleemz asimpleandrapidhighperformanceliquidchromatographicmethodfordeterminingtobramycininpharmaceuticalformulationsbydirectuvdetection
AT khalilpavne asimpleandrapidhighperformanceliquidchromatographicmethodfordeterminingtobramycininpharmaceuticalformulationsbydirectuvdetection
AT muneerams asimpleandrapidhighperformanceliquidchromatographicmethodfordeterminingtobramycininpharmaceuticalformulationsbydirectuvdetection
AT ruckmanik simpleandrapidhighperformanceliquidchromatographicmethodfordeterminingtobramycininpharmaceuticalformulationsbydirectuvdetection
AT shaikhsaleemz simpleandrapidhighperformanceliquidchromatographicmethodfordeterminingtobramycininpharmaceuticalformulationsbydirectuvdetection
AT khalilpavne simpleandrapidhighperformanceliquidchromatographicmethodfordeterminingtobramycininpharmaceuticalformulationsbydirectuvdetection
AT muneerams simpleandrapidhighperformanceliquidchromatographicmethodfordeterminingtobramycininpharmaceuticalformulationsbydirectuvdetection