The new Rapid-i carrier is an effective system for human embryo vitrification at both the blastocyst and cleavage stage
BACKGROUND: The Rapid-i is a new FDA cleared closed carrier for embryo vitrification. The cooling rate of - 1220°C/min is far lower than that reported with open vitrification systems such as the cryoloop (−15,000°C/min). Little published data is currently available on this device. This study present...