Cargando…

High voltage pulsed current stimulation of the sciatic nerve in rats: analysis by the SFI

OBJECTIVE: To analyze the efficiency of high voltage pulsed current (HVPC) with early application in three different sites, in the regeneration of the sciatic nerve in rats submitted to crush injury, the sciatic functional index (SFI) was used to assess the functional recovery. METHODS: After crushi...

Descripción completa

Detalles Bibliográficos
Autores principales: Leoni, Anita Sofia Leite, Mazzer, Nilton, Guirro, Rinaldo Roberto de Jesus, Jatte, Fernanda Guadallini, Chereguini, Paulo Augusto Costa, Monte-Raso, Vanessa Vilela
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Sociedade Brasileira de Ortopedia e Traumatologia Regional de São Paulo 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3718424/
https://www.ncbi.nlm.nih.gov/pubmed/24453588
http://dx.doi.org/10.1590/S1413-78522012000200007