Cargando…

Model Free Approach to Kinetic Analysis of Real-Time Hyperpolarized (13)C Magnetic Resonance Spectroscopy Data

Real-time detection of the rates of metabolic flux, or exchange rates of endogenous enzymatic reactions, is now feasible in biological systems using Dynamic Nuclear Polarization Magnetic Resonance. Derivation of reaction rate kinetics from this technique typically requires multi-compartmental modeli...

Descripción completa

Detalles Bibliográficos
Autores principales: Hill, Deborah K., Orton, Matthew R., Mariotti, Erika, Boult, Jessica K. R., Panek, Rafal, Jafar, Maysam, Parkes, Harold G., Jamin, Yann, Miniotis, Maria Falck, Al-Saffar, Nada M. S., Beloueche-Babari, Mounia, Robinson, Simon P., Leach, Martin O., Chung, Yuen-Li, Eykyn, Thomas R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3762840/
https://www.ncbi.nlm.nih.gov/pubmed/24023724
http://dx.doi.org/10.1371/journal.pone.0071996
_version_ 1782282945339326464
author Hill, Deborah K.
Orton, Matthew R.
Mariotti, Erika
Boult, Jessica K. R.
Panek, Rafal
Jafar, Maysam
Parkes, Harold G.
Jamin, Yann
Miniotis, Maria Falck
Al-Saffar, Nada M. S.
Beloueche-Babari, Mounia
Robinson, Simon P.
Leach, Martin O.
Chung, Yuen-Li
Eykyn, Thomas R.
author_facet Hill, Deborah K.
Orton, Matthew R.
Mariotti, Erika
Boult, Jessica K. R.
Panek, Rafal
Jafar, Maysam
Parkes, Harold G.
Jamin, Yann
Miniotis, Maria Falck
Al-Saffar, Nada M. S.
Beloueche-Babari, Mounia
Robinson, Simon P.
Leach, Martin O.
Chung, Yuen-Li
Eykyn, Thomas R.
author_sort Hill, Deborah K.
collection PubMed
description Real-time detection of the rates of metabolic flux, or exchange rates of endogenous enzymatic reactions, is now feasible in biological systems using Dynamic Nuclear Polarization Magnetic Resonance. Derivation of reaction rate kinetics from this technique typically requires multi-compartmental modeling of dynamic data, and results are therefore model-dependent and prone to misinterpretation. We present a model-free formulism based on the ratio of total areas under the curve (AUC) of the injected and product metabolite, for example pyruvate and lactate. A theoretical framework to support this novel analysis approach is described, and demonstrates that the AUC ratio is proportional to the forward rate constant k. We show that the model-free approach strongly correlates with k for whole cell in vitro experiments across a range of cancer cell lines, and detects response in cells treated with the pan-class I PI3K inhibitor GDC-0941 with comparable or greater sensitivity. The same result is seen in vivo with tumor xenograft-bearing mice, in control tumors and following drug treatment with dichloroacetate. An important finding is that the area under the curve is independent of both the input function and of any other metabolic pathways arising from the injected metabolite. This model-free approach provides a robust and clinically relevant alternative to kinetic model-based rate measurements in the clinical translation of hyperpolarized (13)C metabolic imaging in humans, where measurement of the input function can be problematic.
format Online
Article
Text
id pubmed-3762840
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-37628402013-09-10 Model Free Approach to Kinetic Analysis of Real-Time Hyperpolarized (13)C Magnetic Resonance Spectroscopy Data Hill, Deborah K. Orton, Matthew R. Mariotti, Erika Boult, Jessica K. R. Panek, Rafal Jafar, Maysam Parkes, Harold G. Jamin, Yann Miniotis, Maria Falck Al-Saffar, Nada M. S. Beloueche-Babari, Mounia Robinson, Simon P. Leach, Martin O. Chung, Yuen-Li Eykyn, Thomas R. PLoS One Research Article Real-time detection of the rates of metabolic flux, or exchange rates of endogenous enzymatic reactions, is now feasible in biological systems using Dynamic Nuclear Polarization Magnetic Resonance. Derivation of reaction rate kinetics from this technique typically requires multi-compartmental modeling of dynamic data, and results are therefore model-dependent and prone to misinterpretation. We present a model-free formulism based on the ratio of total areas under the curve (AUC) of the injected and product metabolite, for example pyruvate and lactate. A theoretical framework to support this novel analysis approach is described, and demonstrates that the AUC ratio is proportional to the forward rate constant k. We show that the model-free approach strongly correlates with k for whole cell in vitro experiments across a range of cancer cell lines, and detects response in cells treated with the pan-class I PI3K inhibitor GDC-0941 with comparable or greater sensitivity. The same result is seen in vivo with tumor xenograft-bearing mice, in control tumors and following drug treatment with dichloroacetate. An important finding is that the area under the curve is independent of both the input function and of any other metabolic pathways arising from the injected metabolite. This model-free approach provides a robust and clinically relevant alternative to kinetic model-based rate measurements in the clinical translation of hyperpolarized (13)C metabolic imaging in humans, where measurement of the input function can be problematic. Public Library of Science 2013-09-04 /pmc/articles/PMC3762840/ /pubmed/24023724 http://dx.doi.org/10.1371/journal.pone.0071996 Text en © 2013 Hill et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Hill, Deborah K.
Orton, Matthew R.
Mariotti, Erika
Boult, Jessica K. R.
Panek, Rafal
Jafar, Maysam
Parkes, Harold G.
Jamin, Yann
Miniotis, Maria Falck
Al-Saffar, Nada M. S.
Beloueche-Babari, Mounia
Robinson, Simon P.
Leach, Martin O.
Chung, Yuen-Li
Eykyn, Thomas R.
Model Free Approach to Kinetic Analysis of Real-Time Hyperpolarized (13)C Magnetic Resonance Spectroscopy Data
title Model Free Approach to Kinetic Analysis of Real-Time Hyperpolarized (13)C Magnetic Resonance Spectroscopy Data
title_full Model Free Approach to Kinetic Analysis of Real-Time Hyperpolarized (13)C Magnetic Resonance Spectroscopy Data
title_fullStr Model Free Approach to Kinetic Analysis of Real-Time Hyperpolarized (13)C Magnetic Resonance Spectroscopy Data
title_full_unstemmed Model Free Approach to Kinetic Analysis of Real-Time Hyperpolarized (13)C Magnetic Resonance Spectroscopy Data
title_short Model Free Approach to Kinetic Analysis of Real-Time Hyperpolarized (13)C Magnetic Resonance Spectroscopy Data
title_sort model free approach to kinetic analysis of real-time hyperpolarized (13)c magnetic resonance spectroscopy data
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3762840/
https://www.ncbi.nlm.nih.gov/pubmed/24023724
http://dx.doi.org/10.1371/journal.pone.0071996
work_keys_str_mv AT hilldeborahk modelfreeapproachtokineticanalysisofrealtimehyperpolarized13cmagneticresonancespectroscopydata
AT ortonmatthewr modelfreeapproachtokineticanalysisofrealtimehyperpolarized13cmagneticresonancespectroscopydata
AT mariottierika modelfreeapproachtokineticanalysisofrealtimehyperpolarized13cmagneticresonancespectroscopydata
AT boultjessicakr modelfreeapproachtokineticanalysisofrealtimehyperpolarized13cmagneticresonancespectroscopydata
AT panekrafal modelfreeapproachtokineticanalysisofrealtimehyperpolarized13cmagneticresonancespectroscopydata
AT jafarmaysam modelfreeapproachtokineticanalysisofrealtimehyperpolarized13cmagneticresonancespectroscopydata
AT parkesharoldg modelfreeapproachtokineticanalysisofrealtimehyperpolarized13cmagneticresonancespectroscopydata
AT jaminyann modelfreeapproachtokineticanalysisofrealtimehyperpolarized13cmagneticresonancespectroscopydata
AT miniotismariafalck modelfreeapproachtokineticanalysisofrealtimehyperpolarized13cmagneticresonancespectroscopydata
AT alsaffarnadams modelfreeapproachtokineticanalysisofrealtimehyperpolarized13cmagneticresonancespectroscopydata
AT belouechebabarimounia modelfreeapproachtokineticanalysisofrealtimehyperpolarized13cmagneticresonancespectroscopydata
AT robinsonsimonp modelfreeapproachtokineticanalysisofrealtimehyperpolarized13cmagneticresonancespectroscopydata
AT leachmartino modelfreeapproachtokineticanalysisofrealtimehyperpolarized13cmagneticresonancespectroscopydata
AT chungyuenli modelfreeapproachtokineticanalysisofrealtimehyperpolarized13cmagneticresonancespectroscopydata
AT eykynthomasr modelfreeapproachtokineticanalysisofrealtimehyperpolarized13cmagneticresonancespectroscopydata