Cargando…

Direct Quantification of mRNA and miRNA from Cell Lysates Using Reverse Transcription Real Time PCR: A Multidimensional Analysis of the Performance of Reagents and Workflows

Substantial efforts have been devoted to in vitro testing of candidate chemotherapeutics by profiling transcriptional changes across the collection of NCI-60 cell-lines. A work-flow with reagents that enable the direct quantification of RNA of different molecular sizes simultaneously in the same sam...

Descripción completa

Detalles Bibliográficos
Autores principales: Ho, Yoon Khei, Xu, Wen Ting, Too, Heng Phon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3764000/
https://www.ncbi.nlm.nih.gov/pubmed/24039771
http://dx.doi.org/10.1371/journal.pone.0072463
_version_ 1782283070542446592
author Ho, Yoon Khei
Xu, Wen Ting
Too, Heng Phon
author_facet Ho, Yoon Khei
Xu, Wen Ting
Too, Heng Phon
author_sort Ho, Yoon Khei
collection PubMed
description Substantial efforts have been devoted to in vitro testing of candidate chemotherapeutics by profiling transcriptional changes across the collection of NCI-60 cell-lines. A work-flow with reagents that enable the direct quantification of RNA of different molecular sizes simultaneously in the same sample without laborious total RNA isolation will invariably increase the throughput and accuracy of the study. MicroRNAs (miRNAs) are known to regulate most cellular functions, acting post-transcriptionally by repressing numerous eukaryotic mRNAs. Recent findings on the remarkable stability of miRNA prompted us to investigate the feasibility of quantifying the expression levels of both mRNA and miRNA directly from cell lysates (cell-to-Ct). Multidimensional analyses of the expressions of mRNA and miRNA across seven NCI-60 cell lines and multiple reagents were conducted to assess the performances of these reagents and workflows for cell-to-Ct measurements using reverse transcription-quantitative polymerase chain reaction (RT-qPCR). Quantification of RNA species using lysates prepared from an in-house and one of the commercial reagents demonstrated comparable performance to those prepared by the more laborious and conventional method of using guanidinium-phenol-chloroform. Additionally, miRNA was found to be highly stable in the cell lysates when incubated at room temperature for prolonged period of time and subjected to multiple freeze-thaw cycles. In summary, this study demonstrated significant differences in pre-analytical performance of a variety of commercially available reagents and described a cost-effective reagent useful for rapid, scalable, and high-throughput workflow for the detection of mRNA and miRNA from the same biological sample.
format Online
Article
Text
id pubmed-3764000
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-37640002013-09-13 Direct Quantification of mRNA and miRNA from Cell Lysates Using Reverse Transcription Real Time PCR: A Multidimensional Analysis of the Performance of Reagents and Workflows Ho, Yoon Khei Xu, Wen Ting Too, Heng Phon PLoS One Research Article Substantial efforts have been devoted to in vitro testing of candidate chemotherapeutics by profiling transcriptional changes across the collection of NCI-60 cell-lines. A work-flow with reagents that enable the direct quantification of RNA of different molecular sizes simultaneously in the same sample without laborious total RNA isolation will invariably increase the throughput and accuracy of the study. MicroRNAs (miRNAs) are known to regulate most cellular functions, acting post-transcriptionally by repressing numerous eukaryotic mRNAs. Recent findings on the remarkable stability of miRNA prompted us to investigate the feasibility of quantifying the expression levels of both mRNA and miRNA directly from cell lysates (cell-to-Ct). Multidimensional analyses of the expressions of mRNA and miRNA across seven NCI-60 cell lines and multiple reagents were conducted to assess the performances of these reagents and workflows for cell-to-Ct measurements using reverse transcription-quantitative polymerase chain reaction (RT-qPCR). Quantification of RNA species using lysates prepared from an in-house and one of the commercial reagents demonstrated comparable performance to those prepared by the more laborious and conventional method of using guanidinium-phenol-chloroform. Additionally, miRNA was found to be highly stable in the cell lysates when incubated at room temperature for prolonged period of time and subjected to multiple freeze-thaw cycles. In summary, this study demonstrated significant differences in pre-analytical performance of a variety of commercially available reagents and described a cost-effective reagent useful for rapid, scalable, and high-throughput workflow for the detection of mRNA and miRNA from the same biological sample. Public Library of Science 2013-09-05 /pmc/articles/PMC3764000/ /pubmed/24039771 http://dx.doi.org/10.1371/journal.pone.0072463 Text en © 2013 Ho et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Ho, Yoon Khei
Xu, Wen Ting
Too, Heng Phon
Direct Quantification of mRNA and miRNA from Cell Lysates Using Reverse Transcription Real Time PCR: A Multidimensional Analysis of the Performance of Reagents and Workflows
title Direct Quantification of mRNA and miRNA from Cell Lysates Using Reverse Transcription Real Time PCR: A Multidimensional Analysis of the Performance of Reagents and Workflows
title_full Direct Quantification of mRNA and miRNA from Cell Lysates Using Reverse Transcription Real Time PCR: A Multidimensional Analysis of the Performance of Reagents and Workflows
title_fullStr Direct Quantification of mRNA and miRNA from Cell Lysates Using Reverse Transcription Real Time PCR: A Multidimensional Analysis of the Performance of Reagents and Workflows
title_full_unstemmed Direct Quantification of mRNA and miRNA from Cell Lysates Using Reverse Transcription Real Time PCR: A Multidimensional Analysis of the Performance of Reagents and Workflows
title_short Direct Quantification of mRNA and miRNA from Cell Lysates Using Reverse Transcription Real Time PCR: A Multidimensional Analysis of the Performance of Reagents and Workflows
title_sort direct quantification of mrna and mirna from cell lysates using reverse transcription real time pcr: a multidimensional analysis of the performance of reagents and workflows
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3764000/
https://www.ncbi.nlm.nih.gov/pubmed/24039771
http://dx.doi.org/10.1371/journal.pone.0072463
work_keys_str_mv AT hoyoonkhei directquantificationofmrnaandmirnafromcelllysatesusingreversetranscriptionrealtimepcramultidimensionalanalysisoftheperformanceofreagentsandworkflows
AT xuwenting directquantificationofmrnaandmirnafromcelllysatesusingreversetranscriptionrealtimepcramultidimensionalanalysisoftheperformanceofreagentsandworkflows
AT toohengphon directquantificationofmrnaandmirnafromcelllysatesusingreversetranscriptionrealtimepcramultidimensionalanalysisoftheperformanceofreagentsandworkflows