Stability-indicating HPLC Method for Simultaneous Determination of Montelukast and Fexofenadine Hydrochloride

A simple, specific, accurate, and stability-indicating reversed-phase high-performance liquid chromatographic method was developed for the simultaneous determination of montelukast and fexofenadine hydrochloride, using a Lichrospher(®) 100, RP-18e column and a mobile phase composed of methanol:0.1%...