Cargando…

Evaluation of DNA extraction from granulocytes discarded in the separation medium after isolation of peripheral blood mononuclear cells and plasma from whole blood

BACKGROUND: Whole blood is generally processed for plasma and peripheral blood mononuclear cells (PBMCs) from granulocytes/erythrocytes using gradient centrifugation of blood with Histopaue-Ficoll. After separation of plasma and PBMCs, the residual erythrocytes/granulocytes, a rich source of DNA, is...

Descripción completa

Detalles Bibliográficos
Autores principales: Murray, Janná R, Rajeevan, Mangalathu S
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3818442/
https://www.ncbi.nlm.nih.gov/pubmed/24176175
http://dx.doi.org/10.1186/1756-0500-6-440
_version_ 1782478181083643904
author Murray, Janná R
Rajeevan, Mangalathu S
author_facet Murray, Janná R
Rajeevan, Mangalathu S
author_sort Murray, Janná R
collection PubMed
description BACKGROUND: Whole blood is generally processed for plasma and peripheral blood mononuclear cells (PBMCs) from granulocytes/erythrocytes using gradient centrifugation of blood with Histopaue-Ficoll. After separation of plasma and PBMCs, the residual erythrocytes/granulocytes, a rich source of DNA, is often discarded along with the separation medium. In order to isolate DNA from the granulocytes, current methods require the removal of the separation medium and subsequent purification of granulocytes. This report provides a method for extracting DNA using the PAXgene Blood DNA kit from granulocytes without purifying them from the separation medium. FINDINGS: Based on 719 erythrocyte/granulocyte samples stored frozen for approximately 10 years in Ficoll-Hypaque separation medium, the mean yield of DNA was 395 μg (median = 281 μg; range = 1.36 to 2077.2 μg), with mean A(260)/A(280) ratio of 1.84 (median = 1.84; range = 1.17 to 2.23). The quality of isolated DNA was sufficient for use as a template for restriction enzyme digestion, real-time PCR, pyrosequencing, and gel based variable number tandem repeats (VNTR) genotyping. CONCLUSIONS: By demonstrating the extraction of substantial amounts of high quality granulocytes DNA without purifying them from the separation medium, this method offers laboratories and biobanks a flexible and cost-effective approach to obtain plasma, PBMCs, and large amounts of DNA from a single blood collection for a variety of molecular genetics/epidemiologic studies.
format Online
Article
Text
id pubmed-3818442
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-38184422013-11-07 Evaluation of DNA extraction from granulocytes discarded in the separation medium after isolation of peripheral blood mononuclear cells and plasma from whole blood Murray, Janná R Rajeevan, Mangalathu S BMC Res Notes Short Report BACKGROUND: Whole blood is generally processed for plasma and peripheral blood mononuclear cells (PBMCs) from granulocytes/erythrocytes using gradient centrifugation of blood with Histopaue-Ficoll. After separation of plasma and PBMCs, the residual erythrocytes/granulocytes, a rich source of DNA, is often discarded along with the separation medium. In order to isolate DNA from the granulocytes, current methods require the removal of the separation medium and subsequent purification of granulocytes. This report provides a method for extracting DNA using the PAXgene Blood DNA kit from granulocytes without purifying them from the separation medium. FINDINGS: Based on 719 erythrocyte/granulocyte samples stored frozen for approximately 10 years in Ficoll-Hypaque separation medium, the mean yield of DNA was 395 μg (median = 281 μg; range = 1.36 to 2077.2 μg), with mean A(260)/A(280) ratio of 1.84 (median = 1.84; range = 1.17 to 2.23). The quality of isolated DNA was sufficient for use as a template for restriction enzyme digestion, real-time PCR, pyrosequencing, and gel based variable number tandem repeats (VNTR) genotyping. CONCLUSIONS: By demonstrating the extraction of substantial amounts of high quality granulocytes DNA without purifying them from the separation medium, this method offers laboratories and biobanks a flexible and cost-effective approach to obtain plasma, PBMCs, and large amounts of DNA from a single blood collection for a variety of molecular genetics/epidemiologic studies. BioMed Central 2013-11-01 /pmc/articles/PMC3818442/ /pubmed/24176175 http://dx.doi.org/10.1186/1756-0500-6-440 Text en Copyright © 2013 Murray and Rajeevan; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Short Report
Murray, Janná R
Rajeevan, Mangalathu S
Evaluation of DNA extraction from granulocytes discarded in the separation medium after isolation of peripheral blood mononuclear cells and plasma from whole blood
title Evaluation of DNA extraction from granulocytes discarded in the separation medium after isolation of peripheral blood mononuclear cells and plasma from whole blood
title_full Evaluation of DNA extraction from granulocytes discarded in the separation medium after isolation of peripheral blood mononuclear cells and plasma from whole blood
title_fullStr Evaluation of DNA extraction from granulocytes discarded in the separation medium after isolation of peripheral blood mononuclear cells and plasma from whole blood
title_full_unstemmed Evaluation of DNA extraction from granulocytes discarded in the separation medium after isolation of peripheral blood mononuclear cells and plasma from whole blood
title_short Evaluation of DNA extraction from granulocytes discarded in the separation medium after isolation of peripheral blood mononuclear cells and plasma from whole blood
title_sort evaluation of dna extraction from granulocytes discarded in the separation medium after isolation of peripheral blood mononuclear cells and plasma from whole blood
topic Short Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3818442/
https://www.ncbi.nlm.nih.gov/pubmed/24176175
http://dx.doi.org/10.1186/1756-0500-6-440
work_keys_str_mv AT murrayjannar evaluationofdnaextractionfromgranulocytesdiscardedintheseparationmediumafterisolationofperipheralbloodmononuclearcellsandplasmafromwholeblood
AT rajeevanmangalathus evaluationofdnaextractionfromgranulocytesdiscardedintheseparationmediumafterisolationofperipheralbloodmononuclearcellsandplasmafromwholeblood