Cargando…

A serially coupled stationary phase method for the determination of urinary 8-oxo-7,8-dihydro-2′-deoxyguanosine by liquid chromatography ion trap tandem mass spectrometry()

Oxidative attack to DNA is of particular interest since DNA modifications can lead to heritable mutations. The most studied product of DNA oxidation is 8-oxo-7,8-dihydro-2′-deoxyguanosine (8-oxodG). While 8-oxodG determination in blood and tissue cells is prone to artifacts, its measurement in urine...

Descripción completa

Detalles Bibliográficos
Autores principales: Rota, Cristina, Cristoni, Simone, Trenti, Tommaso, Cariani, Elisabetta
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3830056/
https://www.ncbi.nlm.nih.gov/pubmed/24251117
http://dx.doi.org/10.1016/j.redox.2013.10.001
_version_ 1782291432107671552
author Rota, Cristina
Cristoni, Simone
Trenti, Tommaso
Cariani, Elisabetta
author_facet Rota, Cristina
Cristoni, Simone
Trenti, Tommaso
Cariani, Elisabetta
author_sort Rota, Cristina
collection PubMed
description Oxidative attack to DNA is of particular interest since DNA modifications can lead to heritable mutations. The most studied product of DNA oxidation is 8-oxo-7,8-dihydro-2′-deoxyguanosine (8-oxodG). While 8-oxodG determination in blood and tissue cells is prone to artifacts, its measurement in urine employing liquid chromatography tandem mass spectrometry (LC-MS/MS) has gained more and more interest for increased reliability. LC-MS/MS can be affected by matrix effects and this is particularly true when ion trap is used as MS analyzer, due to ion accumulation in the trap and related space charge effect. In the present work, we have developed a LC-MS/MS method where the combination of cation exchange and reverse phase solid phases resulted in LC separation optimization. This together with the employment of an isotopically labeled internal standard, allowed the usage of ion trap LC-MS/MS, typically not employed for quantitative measurement in biological samples, for the measurement of 8-oxodG in urine samples from control populations. Four different urine matrices were employed for method validation. Limit of quantitation was set at least at 0.5 ng/ml. While analyzing urine samples from healthy volunteers, 8-oxodG levels reported as ng/ml were statistically different comparing males with females (p<0.05, Mann Whitney test); while comparing results normalized for creatinine no statistical significant difference was found. Mean urinary 8-oxodG level found in healthy volunteers was 1.16±0.46 nmol/mmol creatinine. The present method by enhancing at best the chromatographic performances allows the usage of ion trap LC-MS/MS for the measurement of 8-oxodG in urine samples from control populations.
format Online
Article
Text
id pubmed-3830056
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-38300562013-11-18 A serially coupled stationary phase method for the determination of urinary 8-oxo-7,8-dihydro-2′-deoxyguanosine by liquid chromatography ion trap tandem mass spectrometry() Rota, Cristina Cristoni, Simone Trenti, Tommaso Cariani, Elisabetta Redox Biol Research Paper Oxidative attack to DNA is of particular interest since DNA modifications can lead to heritable mutations. The most studied product of DNA oxidation is 8-oxo-7,8-dihydro-2′-deoxyguanosine (8-oxodG). While 8-oxodG determination in blood and tissue cells is prone to artifacts, its measurement in urine employing liquid chromatography tandem mass spectrometry (LC-MS/MS) has gained more and more interest for increased reliability. LC-MS/MS can be affected by matrix effects and this is particularly true when ion trap is used as MS analyzer, due to ion accumulation in the trap and related space charge effect. In the present work, we have developed a LC-MS/MS method where the combination of cation exchange and reverse phase solid phases resulted in LC separation optimization. This together with the employment of an isotopically labeled internal standard, allowed the usage of ion trap LC-MS/MS, typically not employed for quantitative measurement in biological samples, for the measurement of 8-oxodG in urine samples from control populations. Four different urine matrices were employed for method validation. Limit of quantitation was set at least at 0.5 ng/ml. While analyzing urine samples from healthy volunteers, 8-oxodG levels reported as ng/ml were statistically different comparing males with females (p<0.05, Mann Whitney test); while comparing results normalized for creatinine no statistical significant difference was found. Mean urinary 8-oxodG level found in healthy volunteers was 1.16±0.46 nmol/mmol creatinine. The present method by enhancing at best the chromatographic performances allows the usage of ion trap LC-MS/MS for the measurement of 8-oxodG in urine samples from control populations. Elsevier 2013-10-16 /pmc/articles/PMC3830056/ /pubmed/24251117 http://dx.doi.org/10.1016/j.redox.2013.10.001 Text en © 2013 The Authors http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-No Derivative Works License, which permits non-commercial use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Paper
Rota, Cristina
Cristoni, Simone
Trenti, Tommaso
Cariani, Elisabetta
A serially coupled stationary phase method for the determination of urinary 8-oxo-7,8-dihydro-2′-deoxyguanosine by liquid chromatography ion trap tandem mass spectrometry()
title A serially coupled stationary phase method for the determination of urinary 8-oxo-7,8-dihydro-2′-deoxyguanosine by liquid chromatography ion trap tandem mass spectrometry()
title_full A serially coupled stationary phase method for the determination of urinary 8-oxo-7,8-dihydro-2′-deoxyguanosine by liquid chromatography ion trap tandem mass spectrometry()
title_fullStr A serially coupled stationary phase method for the determination of urinary 8-oxo-7,8-dihydro-2′-deoxyguanosine by liquid chromatography ion trap tandem mass spectrometry()
title_full_unstemmed A serially coupled stationary phase method for the determination of urinary 8-oxo-7,8-dihydro-2′-deoxyguanosine by liquid chromatography ion trap tandem mass spectrometry()
title_short A serially coupled stationary phase method for the determination of urinary 8-oxo-7,8-dihydro-2′-deoxyguanosine by liquid chromatography ion trap tandem mass spectrometry()
title_sort serially coupled stationary phase method for the determination of urinary 8-oxo-7,8-dihydro-2′-deoxyguanosine by liquid chromatography ion trap tandem mass spectrometry()
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3830056/
https://www.ncbi.nlm.nih.gov/pubmed/24251117
http://dx.doi.org/10.1016/j.redox.2013.10.001
work_keys_str_mv AT rotacristina aseriallycoupledstationaryphasemethodforthedeterminationofurinary8oxo78dihydro2deoxyguanosinebyliquidchromatographyiontraptandemmassspectrometry
AT cristonisimone aseriallycoupledstationaryphasemethodforthedeterminationofurinary8oxo78dihydro2deoxyguanosinebyliquidchromatographyiontraptandemmassspectrometry
AT trentitommaso aseriallycoupledstationaryphasemethodforthedeterminationofurinary8oxo78dihydro2deoxyguanosinebyliquidchromatographyiontraptandemmassspectrometry
AT carianielisabetta aseriallycoupledstationaryphasemethodforthedeterminationofurinary8oxo78dihydro2deoxyguanosinebyliquidchromatographyiontraptandemmassspectrometry
AT rotacristina seriallycoupledstationaryphasemethodforthedeterminationofurinary8oxo78dihydro2deoxyguanosinebyliquidchromatographyiontraptandemmassspectrometry
AT cristonisimone seriallycoupledstationaryphasemethodforthedeterminationofurinary8oxo78dihydro2deoxyguanosinebyliquidchromatographyiontraptandemmassspectrometry
AT trentitommaso seriallycoupledstationaryphasemethodforthedeterminationofurinary8oxo78dihydro2deoxyguanosinebyliquidchromatographyiontraptandemmassspectrometry
AT carianielisabetta seriallycoupledstationaryphasemethodforthedeterminationofurinary8oxo78dihydro2deoxyguanosinebyliquidchromatographyiontraptandemmassspectrometry