Cargando…
Real-Time Continuous Glucose Monitoring Significantly Reduces Severe Hypoglycemia in Hypoglycemia-Unaware Patients With Type 1 Diabetes
OBJECTIVE: To evaluate the effect of continuous glucose monitoring (CGM) on the frequency of severe hypoglycemia (SH) in patients with established hypoglycemia unawareness. RESEARCH DESIGN AND METHODS: We conducted a retrospective audit of 35 patients with type 1 diabetes and problematic hypoglycemi...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Diabetes Association
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3836107/ https://www.ncbi.nlm.nih.gov/pubmed/24103902 http://dx.doi.org/10.2337/dc13-0939 |